How precise can bony landmarks be determined on a CT scan of the knee?
- PMID: 19195896
- DOI: 10.1016/j.knee.2009.01.001
How precise can bony landmarks be determined on a CT scan of the knee?
Abstract
The purpose of this study was to describe the intra- and inter-observer variability of the registration of bony landmarks and alignment axes on a Computed Axial Tomography (CT) scan. Six cadaver specimens were scanned. Three-dimensional surface models of the knee were created. Three observers marked anatomic surface landmarks and alignment landmarks. The intra- and inter-observer variability of the point and axis registration was performed. Mean intra-observer precision ranks around 1 mm for all landmarks. The intra-class correlation coefficient (ICC) for inter-observer variability ranked higher than 0.98 for all landmarks. The highest recorded intra- and inter-observer variability was 1.3 mm and 3.5 mm respectively and was observed for the lateral femoral epicondyle. The lowest variability in the determination of axes was found for the femoral mechanical axis (intra-observer 0.12 degrees and inter-observer 0.19 degrees) and for the tibial mechanical axis (respectively 0.15 degrees and 0.28 degrees). In the horizontal plane the lowest variability was observed for the posterior condylar line of the femur (intra-observer 0.17 degrees and inter-observer 0.78 degrees) and for the transverse axis (respectively 1.89 degrees and 2.03) on the tibia. This study demonstrates low intra- and inter-observer variability in the CT registration of landmarks that define the coordinate system of the femur and the tibia. In the femur, the horizontal plane projections of the posterior condylar line and the surgical and anatomical transepicondylar axis can be determined precisely on a CT scan, using the described methodology. In the tibia, the best result is obtained for the tibial transverse axis.
Similar articles
-
A common reference frame for describing rotation of the distal femur: a ct-based kinematic study using cadavers.J Bone Joint Surg Br. 2009 May;91(5):683-90. doi: 10.1302/0301-620X.91B5.21827. J Bone Joint Surg Br. 2009. PMID: 19407308
-
Preoperative planning of total knee arthroplasty: reliability of axial alignment using a three-dimensional planning approach.Acta Radiol. 2022 Aug;63(8):1051-1061. doi: 10.1177/02841851211029076. Epub 2021 Jul 6. Acta Radiol. 2022. PMID: 34229468
-
Skeletal landmarks for TKR implantations: evaluation of their accuracy using EOS imaging acquisition system.Orthop Traumatol Surg Res. 2009 Feb;95(1):2-11. doi: 10.1016/j.otsr.2008.05.001. Epub 2009 Feb 3. Orthop Traumatol Surg Res. 2009. PMID: 19251231
-
Rotational alignment of the distal femur: a literature review.Orthop Traumatol Surg Res. 2009 Sep;95(5):365-72. doi: 10.1016/j.otsr.2009.04.011. Epub 2009 Jul 9. Orthop Traumatol Surg Res. 2009. PMID: 19592323 Review.
-
High variability exists in 3D leg alignment analysis, but underlying principles that might lead to agreement on a universal framework could be identified: A systematic review.Knee Surg Sports Traumatol Arthrosc. 2025 Jun;33(6):2063-2077. doi: 10.1002/ksa.12512. Epub 2024 Oct 26. Knee Surg Sports Traumatol Arthrosc. 2025. PMID: 39460613 Free PMC article.
Cited by
-
How reproducible are clinical measurements in robotic knee surgery?J Exp Orthop. 2023 Mar 24;10(1):32. doi: 10.1186/s40634-023-00582-3. J Exp Orthop. 2023. PMID: 36961581 Free PMC article.
-
Association of Femoral Trochlear Dysplasia and Tibiofemoral Joint Morphology in Adolescent.Med Sci Monit. 2019 Mar 8;25:1780-1787. doi: 10.12659/MSM.913600. Med Sci Monit. 2019. PMID: 30849068 Free PMC article.
-
Accuracy and reproducibility analysis of different reference axes for femoral prosthesis rotation alignment in TKA based on 3D CT femoral model.BMC Musculoskelet Disord. 2023 Aug 18;24(1):660. doi: 10.1186/s12891-023-06781-4. BMC Musculoskelet Disord. 2023. PMID: 37596664 Free PMC article.
-
Accuracy of manual and automatic placement of an anatomical coordinate system for the full or partial radius in 3D space.Sci Rep. 2020 May 15;10(1):8114. doi: 10.1038/s41598-020-65060-7. Sci Rep. 2020. PMID: 32415290 Free PMC article.
-
Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs.Knee Surg Sports Traumatol Arthrosc. 2015 Nov;23(11):3343-53. doi: 10.1007/s00167-014-3167-2. Epub 2014 Jul 22. Knee Surg Sports Traumatol Arthrosc. 2015. PMID: 25047792
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical