Clinical performance characteristics of a laboratory test. A practical approach in the autoimmune laboratory
- PMID: 19200856
- DOI: 10.1016/j.autrev.2009.01.013
Clinical performance characteristics of a laboratory test. A practical approach in the autoimmune laboratory
Abstract
Background: This review aims to make laboratory professionals and clinicians more familiar with the basic concepts that deal with the clinical performance characteristics of a laboratory test.
Content: Basic measures of the clinical performance characteristics of a laboratory test, such as sensitivity, specificity, likelihoods, likelihood ratio, post-test probability, odds, Bayes theorem, and receiver-operator characteristic curve are explained. The concepts are illustrated with examples (anti-CCP antibodies) that are worked out in a spreadsheet.
Summary: This review seeks to provide laboratory professionals and clinicians with a better understanding of the clinical performance characteristics of a laboratory test and of evidence-based laboratory medicine. The manuscript emphasizes a strong link between clinical statistics and evidence-based laboratory medicine.
Similar articles
-
Measures of accuracy and performance of diagnostic tests.J Vet Cardiol. 2009 May;11 Suppl 1:S33-40. doi: 10.1016/j.jvc.2009.03.004. Epub 2009 May 17. J Vet Cardiol. 2009. PMID: 19451045 Review.
-
The misuse of predictive value--or why you must consider the odds.Ann Ist Super Sanita. 1991;27(3):395-9. Ann Ist Super Sanita. 1991. PMID: 1809058 Review.
-
Guidelines for the laboratory use of autoantibody tests in the diagnosis and monitoring of autoimmune rheumatic diseases.Am J Clin Pathol. 2002 Feb;117(2):316-24. doi: 10.1309/Y5VF-C3DM-L8XV-U053. Am J Clin Pathol. 2002. PMID: 11863229
-
Evidence-based laboratory medicine - a guide for critical evaluation of in vitro laboratory testing.Ann Clin Biochem. 2007 Mar;44(Pt 2):111-30. doi: 10.1258/000456307780118127. Ann Clin Biochem. 2007. PMID: 17362577 Review.
-
Advantages to transforming the receiver operating characteristic (ROC) curve into likelihood ratio co-ordinates.Stat Med. 2005 Apr 30;24(8):1287-8; author reply 1288. doi: 10.1002/sim.2028. Stat Med. 2005. PMID: 15765500 No abstract available.
Cited by
-
Are There Associations between Seminal Plasma Advanced Oxidation Protein Products and Selected Redox-Associated Biochemical Parameters in Infertile Male Patients? A Preliminary Report.Cells. 2022 Nov 18;11(22):3667. doi: 10.3390/cells11223667. Cells. 2022. PMID: 36429095 Free PMC article.
-
Multi-center evaluation of autoantibodies to the major ribosomal P C22 epitope.Rheumatol Int. 2012 Mar;32(3):691-8. doi: 10.1007/s00296-010-1685-x. Epub 2010 Dec 8. Rheumatol Int. 2012. PMID: 21140265
-
A high sensitivity assay is more accurate than a classical assay for the measurement of plasma CRP levels in endometriosis.Reprod Biol Endocrinol. 2011 Aug 9;9:113. doi: 10.1186/1477-7827-9-113. Reprod Biol Endocrinol. 2011. PMID: 21827658 Free PMC article.
-
Deoxyribonuclease activity of polyclonal IgGs: a putative serological marker in patients with spondyloarthritides.Immunol Res. 2013 Jul;56(2-3):457-64. doi: 10.1007/s12026-013-8424-9. Immunol Res. 2013. PMID: 23592052
-
Routine use of Zenit RA, a novel chemiluminescent immunoanalyzer in autoimmune disease diagnosis.Auto Immun Highlights. 2012 Mar 21;3(1):27-31. doi: 10.1007/s13317-012-0032-5. eCollection 2012 Apr. Auto Immun Highlights. 2012. PMID: 26000125 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical