Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Jan-Feb;3(1):24-31.
doi: 10.1016/j.jcct.2008.12.005. Epub 2008 Dec 25.

Assessment of nonstenotic coronary lesions by 64-slice multidetector computed tomography in comparison to intravascular ultrasound: evaluation of nonculprit coronary lesions

Affiliations
Comparative Study

Assessment of nonstenotic coronary lesions by 64-slice multidetector computed tomography in comparison to intravascular ultrasound: evaluation of nonculprit coronary lesions

Milena Petranovic et al. J Cardiovasc Comput Tomogr. 2009 Jan-Feb.

Abstract

Background: Multidetector computed tomography (MDCT) has recently emerged as a potential noninvasive alternative for high-resolution imaging of coronary arteries.

Objective: In this study, we evaluated 64-slice MDCT for detection, quantification, and characterization of atherosclerotic plaque burden in nonculprit lesions.

Methods: Data from 11 patients who underwent both MDCT and intravascular ultrasound (IVUS) for suspected coronary artery disease were collected, and a total of 17 coronary segments and 122 cross-sectional slices were analyzed by MDCT and IVUS. Coronary segments on MDCT were coregistered to IVUS, and each obtained slice was scored by 2 blinded observers for presence and type of plaque. Quantitative measurements included cross-sectional vessel area, lumen area, wall area, plaque volume, and plaque burden. Mean and standard deviation of Hounsfield units (HUs) were recorded for plaque when present.

Results: Overall sensitivity for plaque detection was 95.0%, and specificity, positive predictive value, negative predictive value were 88.7%, 89.1%, and 94.8%, respectively. Spearman's correlation coefficients were 0.85, 0.75, 0.70, 0.89, and 0.54 for cross-sectional vessel area, lumen area, wall area, plaque volume, and plaque burden, respectively. The interobserver variability for plaque burden and plaque volume measurements between readers on 64-MDCT was high at 32.7% and 30.4%, respectively. Combined noncalcified plaque had a mean MDCT density significantly different from that of calcified plaque. Soft and fibrous plaques were not able to be distinguished based on their HU values.

Conclusion: Sixty-four-slice MDCT had good correlation with IVUS but with high interobserver variability. Plaque characterization remains a challenge with present MDCT technology.

PubMed Disclaimer

Comment in

Publication types

MeSH terms