Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Apr;109(3):215-24.
doi: 10.1016/j.envres.2008.12.010. Epub 2009 Feb 8.

Aerosolization of fungi, (1-->3)-beta-D glucan, and endotoxin from flood-affected materials collected in New Orleans homes

Affiliations

Aerosolization of fungi, (1-->3)-beta-D glucan, and endotoxin from flood-affected materials collected in New Orleans homes

Atin Adhikari et al. Environ Res. 2009 Apr.

Abstract

Standing water and sediments remaining on flood-affected materials were the breeding ground for many microorganisms in flooded homes following Hurricane Katrina. The purpose of this laboratory study was to examine the aerosolization of culturable and total fungi, (1-->3)-beta-D glucan, and endotoxin from eight flood-affected floor and bedding materials collected in New Orleans homes, following Hurricane Katrina. Aerosolization was examined using the Fungal Spore Source Strength Tester (FSSST) connected to a BioSampler. Dust samples were collected by vacuuming. A two-stage cyclone sampler was used for size-selective analysis of aerosolized glucan and endotoxin. On average, levels of culturable fungi ranged from undetectable (lower limit=8.3 x 10(4)) to 2.6 x 10(5) CFU/m(2); total fungi ranged from 2.07 x 10(5) to 1.6 x 10(6) spores/m(2); (1-->3)-beta-D glucan and endotoxin were 2.0 x 10(3) - 2.9 x 10(4) ng/m(2) and 7.0 x 10(2) - 9.3 x 10(4) EU/m(2), respectively. The results showed that 5-15 min sampling is sufficient for detecting aerosolizable biocontaminants with the FSSST. Smaller particle size fractions (<1.0 and <1.8 microm) have levels of glucan and endotoxin comparable to larger (>1.8 microm) fractions, which raises additional exposure concerns. Vacuuming was found to overestimate inhalation exposure risks by a factor of approximately 10(2) for (1-->3)-beta-D glucan and by 10(3)-10(4) for endotoxin as detected by the FSSST. The information generated from this study is important with respect to restoration and rejuvenation of the flood-affected areas in New Orleans. We believe the findings will be significant during similar disasters in other regions of the world including major coastal floods from tsunamis.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Experimental set-up to test the aerosolization of biocontaminants (Set-up – I) and size-selective measurement of aerosolized biocontaminants (Set-up – II).
Figure 2
Figure 2
(1→3)-β-D-glucan aerosolized from contaminated materials collected in flood-affected homes of New Orleans. The histograms present geometric mean of three replicates and error bars indicate geometric standard deviations.
Figure 3
Figure 3
(1→3)-β-D-glucan aerosolized from different floor and bedding materials collected in flood-affected homes of New Orleans (presented size-selectively). The histograms present geometric mean of three replicates and error bars indicate geometric standard deviations.
Figure 4
Figure 4
Endotoxin aerosolized from contaminated materials collected in flood-affected homes of New Orleans. The histograms present geometric mean of three replicates and error bars indicate geometric standard deviations.
Figure 5
Figure 5
Endotoxin aerosolized from different floor and bedding materials collected in flood-affected homes of New Orleans (presented size-selectively). The histograms present geometric mean of three replicates and error bars indicate geometric standard deviations. Star signs indicate

References

    1. Adhikari A, Martuzevicius D, Reponen T, Grinshpun SA, Cho S-H, Sivasubramani SK, Zhong W, Levin L, Kelley AL, St. Clair H, LeMasters G. Performance of the Button Personal Inhalable Sampler for the measurement of outdoor aeroallergens. Atmos. Environ. 2003;34:4723–4733.
    1. American Lung Association [30 May 2008];Flood Clean-Up Fact Sheet. 2008 Available: http://www.lungusa.org/site/pp.asp?c=dvLUK9O0E&b=35694.
    1. Asselt LV. Interactions between domestic mites and fungi. Indoor Built Environ. 1999;8:216–220.
    1. Burge HA. Fungi: toxic killers or unavoidable nuisance? Ann. Allergy Asthma Immunol. 2001;87(Suppl. 3):52–56. - PubMed
    1. Centers for Disease Control and Prevention . Morb. Mortal. Wkly. Rep. Vol. 55. Louisiana: Oct, 2006. 2005. Health concerns associated with mold in water-damaged homes after Hurricanes Katrina and Rita—New Orleans area; pp. 41–44. - PubMed

Publication types