Preclinical in vivo evaluation of an extracorporeal HIFU device for ablation of pancreatic tumors
- PMID: 19201519
- DOI: 10.1016/j.ultrasmedbio.2008.12.006
Preclinical in vivo evaluation of an extracorporeal HIFU device for ablation of pancreatic tumors
Abstract
Extracorporeal high-intensity focused ultrasound (HIFU) can be used to ablate tissue noninvasively by delivering focused ultrasound energy from an external source. HIFU for clinical treatment of pancreatic cancer has been reported; however, systematic evaluation of the safety and efficacy of pancreatic ablation with HIFU has not been performed. The objectives of this in vivo study are as follows: (1) assess the safety and feasibility of targeting and ablating pancreatic tissue using the FEP-BY02 HIFU system (Yuande Bio-Medical Engineering, Beijing, China); (2) evaluate a method for estimating in situ acoustic treatment energy in an in vivo setting; and (3) identify the optimal treatment parameters that result in safe and effective ablation of the pancreas. The pancreata of 12 common swine were treated in vivo. Prior to therapy, blood was drawn for laboratory analysis. Animals were then treated with extracorporeal HIFU at three different acoustic treatment energies (750, 1000 and 1250 J). Endoscopy was performed prior to and immediately following HIFU therapy to assess for gastric injury. Blood was drawn after completion of the treatment and on days 2 and 7 following treatment to assess for biochemical evidence of pancreatitis. Animals were then euthanized 7 d following treatment and a necropsy was performed to assess for unintended injury and to obtain pancreatic tissue for histology to assess efficacy of HIFU ablation. Histologic scoring of pancreatic tissue changes was performed by a pathologist blinded to the treatment energy delivered. The degree of ablation identified on histology correlated with the treatment energy. No collateral tissue damage was seen at treatment energies of 750 and 1000 J. At 1250 J, thermal injury to the abdominal muscles and gastric ulcers were observed. There were no premature deaths, serious illnesses, skin burns or evidence of pancreatitis on biochemical analysis. HIFU treatment of the pancreas is feasible, safe and can be used to ablate tissue noninvasively. A clinical trial in humans examining the use of extracorporeal HIFU for palliation of pain related to pancreatic cancer is planned.
Similar articles
-
Experimental ablation of the pancreas with high intensity focused ultrasound (HIFU) in a porcine model.Int J Med Sci. 2010 Dec 17;8(1):9-15. doi: 10.7150/ijms.8.9. Int J Med Sci. 2010. PMID: 21197259 Free PMC article.
-
Thermal Ablation of the Pancreas With Intraoperative High-Intensity Focused Ultrasound: Safety and Efficacy in a Porcine Model.Pancreas. 2017 Feb;46(2):219-224. doi: 10.1097/MPA.0000000000000720. Pancreas. 2017. PMID: 27841792
-
Evaluation of a novel high-intensity focused ultrasound device: preclinical studies in a porcine model.Aesthet Surg J. 2011 May;31(4):429-34. doi: 10.1177/1090820X11405026. Aesthet Surg J. 2011. PMID: 21551434
-
Advances of high intensity focused ultrasound (HIFU) for pancreatic cancer.Int J Hyperthermia. 2013 Nov;29(7):678-82. doi: 10.3109/02656736.2013.837199. Int J Hyperthermia. 2013. PMID: 24102396 Review.
-
High intensity focused ultrasound: a noninvasive therapy for locally advanced pancreatic cancer.World J Gastroenterol. 2014 Nov 28;20(44):16480-8. doi: 10.3748/wjg.v20.i44.16480. World J Gastroenterol. 2014. PMID: 25469016 Free PMC article. Review.
Cited by
-
An in vivo study of the effects on serum glucose, amylase and histopathology of the feline pancreatic tissue treated by focused ultrasound.PLoS One. 2014 Feb 18;9(2):e88815. doi: 10.1371/journal.pone.0088815. eCollection 2014. PLoS One. 2014. PMID: 24558434 Free PMC article.
-
Factors affecting tumor ablation during high intensity focused ultrasound treatment.Gut Liver. 2014 Jul;8(4):433-7. doi: 10.5009/gnl.2014.8.4.433. Epub 2013 Dec 24. Gut Liver. 2014. PMID: 25071910 Free PMC article.
-
Focused ultrasound to displace renal calculi: threshold for tissue injury.J Ther Ultrasound. 2014 Mar 31;2:5. doi: 10.1186/2050-5736-2-5. eCollection 2014. J Ther Ultrasound. 2014. PMID: 24921046 Free PMC article.
-
Nanoparticle-Mediated Acoustic Cavitation Enables High Intensity Focused Ultrasound Ablation Without Tissue Heating.ACS Appl Mater Interfaces. 2018 Oct 31;10(43):36786-36795. doi: 10.1021/acsami.8b15368. Epub 2018 Oct 19. ACS Appl Mater Interfaces. 2018. PMID: 30339360 Free PMC article.
-
Employing Novel Porcine Models of Subcutaneous Pancreatic Cancer to Evaluate Oncological Therapies.Methods Mol Biol. 2022;2394:883-895. doi: 10.1007/978-1-0716-1811-0_47. Methods Mol Biol. 2022. PMID: 35094364
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical