Certification of beryllium mass fraction in SRM 1877 Beryllium Oxide Powder using high-performance inductively coupled plasma optical emission spectrometry with exact matching
- PMID: 19209906
- DOI: 10.1021/ac802251n
Certification of beryllium mass fraction in SRM 1877 Beryllium Oxide Powder using high-performance inductively coupled plasma optical emission spectrometry with exact matching
Abstract
High-performance inductively coupled plasma optical emission spectrometry (HP-ICP-OES) was used to certify the Be mass fraction in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1877 Beryllium Oxide Powder. The certified value and expanded uncertainty expressed at a 95% confidence level is (0.3576 +/- 0.0024) g/g. To obtain best results, the Be mass fractions, Mn (internal standard) mass fractions, and matrix compositions of the calibration solutions were carefully matched to those of the sample solutions for each individual HP-ICP-OES analysis. This "exact matching" approach was used because experience at NIST has shown that it often affords improved accuracy and precision in HP-ICP-OES analysis. NIST has never published these observations. Due to the toxicity of BeO and the difficulty of containing the very fine powder material, sets of solutions for HP-ICP-OES analysis were prepared by laboratories collaborating with NIST who have the experience and equipment needed to work with the material safely. Each laboratory utilized a unique digestion protocol(s). After preparing the sets of solutions, the collaborating laboratories shipped them to NIST for HP-ICP-OES analysis. NIST provided the collaborating laboratories with solution preparation kits and spreadsheets to help establish traceability of the HP-ICP-OES results to the International System of Units (SI) and to allow exact matching to be accomplished. The agreement observed among the four individual Be mass fraction values determined from the sets of solutions prepared by the collaborating laboratories was 0.074% relative (1s of mean). The excellent agreement provides a measure of confidence in the robustness of each of the digestion procedures, as well as in the certified Be mass fraction value. The analytical benefits of using exact matching for this particular certification were investigated. Results show that exactly matching the matrix compositions of the standards to the samples for each HP-ICP-OES analysis was critical to obtaining the excellent agreement observed among the individual Be mass fraction values and also helped to minimize bias and uncertainty in the certified value. Unlike previous NIST studies, exactly matching the Be and Mn mass fractions of the standards to the samples for this particular certification appears to have had little effect on the data.
Similar articles
-
Improving the high-performance inductively coupled plasma optical emission spectrometry methodology through exact matching.Anal Chem. 2010 Sep 15;82(18):7675-83. doi: 10.1021/ac101471a. Anal Chem. 2010. PMID: 20795649
-
Preparation, certification and interlaboratory analysis of workplace air filters spiked with high-fired beryllium oxide.J Environ Monit. 2012 Feb;14(2):391-401. doi: 10.1039/c1em10688k. Epub 2011 Oct 28. J Environ Monit. 2012. PMID: 22025111
-
Effect of valence state on ICP-OES value assignment of SRM 3103a arsenic spectrometric solution.Anal Chem. 2006 Mar 1;78(5):1651-6. doi: 10.1021/ac051732i. Anal Chem. 2006. PMID: 16503619
-
Recent Advances in the Determination of Major and Trace Elements in Plants Using Inductively Coupled Plasma Optical Emission Spectrometry.Molecules. 2024 Jul 3;29(13):3169. doi: 10.3390/molecules29133169. Molecules. 2024. PMID: 38999125 Free PMC article. Review.
-
Method for Determination of the Mass Fraction of Particle-Bound Gold in Suspensions of Gold Nanoparticles: Version 1.2.2024 Jul. In: National Cancer Institute’s Nanotechnology Characterization Laboratory Assay Cascade Protocols [Internet]. Bethesda (MD): National Cancer Institute (US); 2005 May 1–. NIST - NCL Joint Assay Protocol, PCC-11. 2024 Jul. In: National Cancer Institute’s Nanotechnology Characterization Laboratory Assay Cascade Protocols [Internet]. Bethesda (MD): National Cancer Institute (US); 2005 May 1–. NIST - NCL Joint Assay Protocol, PCC-11. PMID: 39999268 Free Books & Documents. Review.
Cited by
-
Regulatory T cells modulate granulomatous inflammation in an HLA-DP2 transgenic murine model of beryllium-induced disease.Proc Natl Acad Sci U S A. 2014 Jun 10;111(23):8553-8. doi: 10.1073/pnas.1408048111. Epub 2014 May 27. Proc Natl Acad Sci U S A. 2014. PMID: 24912188 Free PMC article.
-
Protective role of B cells in sterile particulate-induced lung injury.JCI Insight. 2019 May 16;5(12):e125494. doi: 10.1172/jci.insight.125494. JCI Insight. 2019. PMID: 31094704 Free PMC article.
-
Interleukin-1 signaling and CD4+ T cells control B cell recruitment to the lungs in chronic beryllium disease.Front Immunol. 2025 Jan 28;16:1479348. doi: 10.3389/fimmu.2025.1479348. eCollection 2025. Front Immunol. 2025. PMID: 39935485 Free PMC article.
-
Comparison of different characterization approaches for monoelemental calibration solutions at two national metrology institutes.Anal Bioanal Chem. 2025 May;417(12):2603-2616. doi: 10.1007/s00216-025-05731-4. Epub 2025 Jan 16. Anal Bioanal Chem. 2025. PMID: 39821331 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous