[A new total knee arthroplasty with physiologically shaped surfaces. Part 2: First clinical results]
- PMID: 19212737
- DOI: 10.1007/s00113-008-1551-4
[A new total knee arthroplasty with physiologically shaped surfaces. Part 2: First clinical results]
Abstract
The human medial tibial plateau is concave, whereas the lateral tibial plateau is convex. In a normal knee, the convex femoral condyles roll and glide on the tibia during the standing phase of walking. The designs of most commercially available knee prostheses do not take this morphological feature into consideration. The novel design of the AEQUOS G1 knee replacement prosthesis is based on the natural anatomy of the knee joint, with a convex lateral tibia plateau and a sagittal offset of the medial and lateral compartments. Following extensive development and testing, initial clinical results of the AEQUOS G1 prosthesis in a mulitcenter study are presented. From Mai 2005 to March 2007, 158 patients in 4 clinics underwent total knee arthroplasty with the AEQUOS G1 and agreed to participate in the study. Patients were evaluated preoperatively and at 3, 6 and 12 months of follow-up using a standardized protocol that included the American Knee Society Score (AKSS), the Oxford Knee Score (OKS) and the Visual Analog Scale (VAS) for pain. After 3 months, 151 patients appeared for follow up appointments, after 6 months, 134, and after 12 months, 127. The mean range of motion preoperatively was 97.0 degrees (+/-19.9 degrees ) and 107.5 degrees (+/-15.9 degrees ) 12 months after surgery. The AKSS, as well as the modified OKS, significantly improved (p<0.0001) from preoperative scores of 98.8 (+/-35.8) and 37.3 (+/-6.9) points, respectively, to 165.8 (+/-34.1) and 21.9 (+/-7.8) points, preoperatively, and 12 months postoperatively. The VAS score significantly decreased (p<0.001) from 7.4 (+/-1.8) points preoperatively to 1.9 (+/-2.2) points 12 months postoperatively.One implant was revised because of arthrofibrosis and another due to patellar luxation. Two patients required revision because their implants revealed malalignement with ligamentous instability. No infections, aseptic loosening or other implant-specific complications were observed at this early follow-up. Good clinical results were observed at early follow-up with the AEQUOS G1 knee arthroplasty. However, longer follow-up is necessary for a general evaluation of the implant.
Similar articles
-
[Knee revision arthroplasty : cementless, metaphyseal fixation with sleeves].Oper Orthop Traumatol. 2015 Feb;27(1):24-34. doi: 10.1007/s00064-014-0333-0. Epub 2015 Jan 28. Oper Orthop Traumatol. 2015. PMID: 25620192 Clinical Trial. German.
-
[The bicompartmental knee joint prosthesis Journey Deuce: failure analysis and optimization strategies].Orthopade. 2012 Nov;41(11):894-904. doi: 10.1007/s00132-012-1963-2. Orthopade. 2012. PMID: 22777482 Clinical Trial. German.
-
Bicompartmental individualized knee replacement : Use of patient-specific implants and instruments (iDuo™).Oper Orthop Traumatol. 2017 Feb;29(1):51-58. doi: 10.1007/s00064-017-0484-x. Epub 2017 Jan 31. Oper Orthop Traumatol. 2017. PMID: 28144716 Clinical Trial. English.
-
[Total knee arthroplasty with the Beznoska S.V.L. implant: short-term results].Acta Chir Orthop Traumatol Cech. 2004;71(6):352-9. Acta Chir Orthop Traumatol Cech. 2004. PMID: 15686636 Czech.
-
Total knee replacement with natural rollback.Ann Anat. 2012 Mar 20;194(2):195-9. doi: 10.1016/j.aanat.2011.01.013. Epub 2011 Mar 17. Ann Anat. 2012. PMID: 21493053 Review.
Cited by
-
[Early results of gender-specific posterior stabilized total knee arthroplasty without patella resurfacing].Orthopade. 2013 Oct;42(10):866-73. doi: 10.1007/s00132-013-2139-4. Orthopade. 2013. PMID: 23812209 Clinical Trial. German.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical