A modified power-law formula for inhomogeneity corrections in beams of high-energy x rays
- PMID: 1921876
- DOI: 10.1118/1.596665
A modified power-law formula for inhomogeneity corrections in beams of high-energy x rays
Abstract
The Batho power-law formula is in common use in many treatment planning systems to correct for the presence of lungs and other inhomogeneities. While giving excellent agreement with measurement for Cobalt-60 radiation, it tends to underestimate the lung correction required for higher energy x rays and is undefined for distances beyond an interface less than the buildup distance. This paper suggests a simple modification that greatly improves the agreement with measured data and gives a continuously defined function at all depths. Measurements have been made in a polystyrene and cork phantom to simulate the effects of lung; data are presented for beams of 8-MV x rays, 16-MV x rays, and Cobalt-60 gamma rays.
Similar articles
-
A comparison of air-cavity inhomogeneity effects for cobalt-60, 6-, and 10-MV x-ray beams.Med Phys. 1987 Jan-Feb;14(1):140-4. doi: 10.1118/1.596101. Med Phys. 1987. PMID: 3104739
-
Effect of low-density lateral interfaces on soft-tissue doses.Int J Radiat Oncol Biol Phys. 1997 Jan 15;37(2):475-82. doi: 10.1016/s0360-3016(96)00499-3. Int J Radiat Oncol Biol Phys. 1997. PMID: 9069324
-
Implications of computed tomography for inhomogeneity corrections in photon beam dose calculations.Radiology. 1977 Jul;124(1):143-9. doi: 10.1148/124.1.143. Radiology. 1977. PMID: 405707
-
Improved lung dose calculation using tissue-maximum ratios in the Batho correction.Med Phys. 1984 May-Jun;11(3):279-86. doi: 10.1118/1.595495. Med Phys. 1984. PMID: 6429498
-
Radial distribution of dose.Basic Life Sci. 1991;58:163-79; discussion 179-80. doi: 10.1007/978-1-4684-7627-9_6. Basic Life Sci. 1991. PMID: 1811472 Review.
Cited by
-
Impact of dose calculation models on radiotherapy outcomes and quality adjusted life years for lung cancer treatment: do we need to measure radiotherapy outcomes to tune the radiobiological parameters of a normal tissue complication probability model?Transl Lung Cancer Res. 2016 Dec;5(6):673-680. doi: 10.21037/tlcr.2016.11.04. Transl Lung Cancer Res. 2016. PMID: 28149761 Free PMC article.
-
Dosimetric effects near implanted vascular access ports: an examination of external photon beam calculation.J Appl Clin Med Phys. 2009 May 28;10(3):3-15. doi: 10.1120/jacmp.v10i3.2886. J Appl Clin Med Phys. 2009. PMID: 19692972 Free PMC article.
-
Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study.J Biomed Phys Eng. 2019 Feb 1;9(1):17-28. eCollection 2019 Feb. J Biomed Phys Eng. 2019. PMID: 30881931 Free PMC article.
-
Agreement between gamma passing rates using computed tomography in radiotherapy and secondary cancer risk prediction from more advanced dose calculated models.Quant Imaging Med Surg. 2017 Jun;7(3):292-298. doi: 10.21037/qims.2017.06.03. Quant Imaging Med Surg. 2017. PMID: 28811995 Free PMC article.
-
Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife.J Appl Clin Med Phys. 2015 Sep 8;16(5):193-204. doi: 10.1120/jacmp.v16i5.5397. J Appl Clin Med Phys. 2015. PMID: 26699300 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources