Determination of Oversulphated Chondroitin Sulphate and Dermatan Sulphate in unfractionated heparin by (1)H-NMR - Collaborative study for quantification and analytical determination of LoD
- PMID: 19220979
Determination of Oversulphated Chondroitin Sulphate and Dermatan Sulphate in unfractionated heparin by (1)H-NMR - Collaborative study for quantification and analytical determination of LoD
Abstract
Oversulphated Chondroitin Sulphate (OSCS) and Dermatan Sulphate (DS) in unfractionated heparins can be identified by nuclear magnetic resonance spectrometry (NMR). The limit of detection (LoD) of OSCS is 0.1% relative to the heparin content. This LoD is obtained at a signal-to-noise ratio (S/N) of 2000:1 of the heparin methyl signal. Quantification is best obtained by comparing peak heights of the OSCS and heparin methyl signals. Reproducibility of less than 10% relative standard deviation (RSD) has been obtained. The accuracy of quantification was good.
Similar articles
-
Identification and purity test of heparin by NMR - a summary of two years' experience at the Medical Products Agency.Pharmeur Bio Sci Notes. 2010 Apr;2010(1):65-72. Pharmeur Bio Sci Notes. 2010. PMID: 20223191 Review.
-
Effect of Ca2+ on the 1H NMR chemical shift of the methyl signal of oversulphated chondroitin sulphate, a contaminant in heparin.J Pharm Biomed Anal. 2009 Apr 5;49(3):816-9. doi: 10.1016/j.jpba.2008.12.012. Epub 2008 Dec 24. J Pharm Biomed Anal. 2009. PMID: 19179033
-
Prediction of the oversulphated chondroitin sulphate contamination of unfractionated heparin by ATR-IR spectrophotometry.Pharmeur Sci Notes. 2009 Mar;2009(1):17-24. Pharmeur Sci Notes. 2009. PMID: 19275869
-
Composition of OSCS-contaminated heparin occurring in 2008 in batches on the German market.Eur J Pharm Sci. 2010 Jul 11;40(4):297-304. doi: 10.1016/j.ejps.2010.04.002. Epub 2010 Apr 23. Eur J Pharm Sci. 2010. PMID: 20399266
-
Case study: contamination of heparin with oversulfated chondroitin sulfate.Handb Exp Pharmacol. 2012;(207):99-125. doi: 10.1007/978-3-642-23056-1_6. Handb Exp Pharmacol. 2012. PMID: 22566223 Review.