Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Aug;18(6):488-91.
doi: 10.1097/IJG.0b013e31818fb44e.

Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery

Affiliations
Comparative Study

Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery

Elliott M Kanner et al. J Glaucoma. 2009 Aug.

Abstract

Purpose: Our purpose was to evaluate the clinical outcomes of the Ex-PRESS miniature glaucoma device placed under a partial-thickness scleral flap as a single procedure or combined with phacoemulsification cataract surgery.

Methods: This was a comparative consecutive case series of 345 eyes: 231 eyes treated with Ex-PRESS implant under scleral flap alone and 114 eyes treated with Ex-PRESS implant under scleral flap combined with phacoemulsification (both groups were treated intraoperatively with mitomycin C).

Results: The patients were followed for 25.7+/-11.1 (range, 1 to 46.2) months (Ex-PRESS alone) and 21.9+/-12.5 (range, 1.9 to 46.2) months (combined cases). At 3 years after surgery, surgical success was 94.8% and 95.6% in the Ex-PRESS and combined groups, respectively (P=0.948). Compared with baseline values, the postoperative intraocular pressure (IOP) and number of glaucoma medications were significantly lowered in both groups. The change from baseline IOP was significantly greater after Ex-PRESS implant alone compared with combined surgery (P<0.001). The most common device-related complication was obstruction of the tube (6 eyes), which was treated successfully with Nd:YAG laser in all 6 eyes.

Conclusions: The use of the Ex-PRESS implant under a scleral flap was effective for lowering IOP both alone and combined with cataract surgery. The most common device-related complication was tube blockage, which was treated with the Nd:YAG laser.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources