. 2010 Jan;12(1):104-10.
doi: 10.1038/aja.2008.41. Epub 2009 Feb 23.

A survey on the status of semen analysis in 118 laboratories in China

Affiliations

A survey on the status of semen analysis in 118 laboratories in China

Jin-Chun Lu et al. Asian J Androl. 2010 Jan.

Abstract

Collecting baseline information on how laboratories perform testing is a reasonable first step towards establishing intra- and inter-laboratory standardization and quality control for semen analysis. We carried out a survey of the laboratories performing the testing in Mainland China. A questionnaire, composed of 36 questions covering all aspects of semen analysis, was designed, and a copy was distributed to each of the 145 laboratories. Of these, 118 laboratories completed the questionnaires. The survey results showed that semen volume was measured visually in 53.6% (59/110) of the responding laboratories, and 70.9% (73/103) of laboratories analysed incompletely liquefied semen without any treatment. In addition, both manual-microscopic and computer-assisted semen-analysis systems were applied to analyse sperm concentration, motility and morphology. However, more than five methods were employed in routine sperm staining. An enzyme-linked immunosorbent assay was commonly used for determining whether antisperm antibodies were present. Several seminal biochemical markers were analysed in only 27.1% (32/118) of the responding laboratories. Generally, there was a lack of intra- and inter-laboratory quality control measures for semen analysis in all laboratories responding to this survey. In conclusion, the methods of semen analysis and the interpretation of test results in the surveyed laboratories differed markedly. In particular, many laboratories employed methods other than those recommended by the World Health Organization Laboratory Manual for the Examination of Human Semen and Spermcervical Mucus Interaction (1999). These findings suggest an urgent need for the standardization of semen analysis with acceptable quality controls for each parameter to make the results repeatable and meaningful.

PubMed Disclaimer

Comment in

References

    1. Keel BA. Quality control, quality assurance, and proficiency testing in the andrology laboratory. Arch Androl. 2002;48:417–31. - PubMed
    1. Keel BA. How reliable are results from the semen analysis. Fertil Steril. 2004;82:41–4. - PubMed
    1. Baker DJ, Paterson MA, Klaassen JM, Wyrick-Glatzel J. Semen evaluation in the clinical laboratory: How well are they being performed. Lab Med. 1994;25:509–14.
    1. Baker DJ. Semen analysis. Clin Lab Sci. 2007;20:172–87. - PubMed
    1. Huang YF, Li PS. Urgent need for the standardization of semen analysis among clinical andrology laboratories. Zhonghua Nan Ke Xue. 2005;11:83–4. - PubMed