Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009;10(3):326-35.
doi: 10.1007/s12028-009-9199-7. Epub 2009 Feb 24.

Transcranial Doppler ultrasonography in the assessment of cerebral circulation arrest: improving sensitivity by transcervical and transorbital carotid insonation and serial examinations

Affiliations

Transcranial Doppler ultrasonography in the assessment of cerebral circulation arrest: improving sensitivity by transcervical and transorbital carotid insonation and serial examinations

Alfredo Conti et al. Neurocrit Care. 2009.

Abstract

Introduction: Transcranial Doppler (TCD) can detect the cerebral circulation arrest (CCA) in brain death. TCD is highly specific, but less sensitive because of false-negatives accounting for up to 10%. The aim of the study was to explore the diagnostic accuracy of TCD and to determine whether it can be augmented by strategies such as the insonation of the extracranial internal carotid artery (ICA) and sequential examinations.

Methods: Data of 184 patients, who met clinical criteria of brain death, observed from 1998 through 2006, were retrospectively reviewed. The study of cerebral arteries was performed through the transtemporal approach, suboccipital insonation of the vertebro-basilar system, transorbital insonation of the ICA and ophthalmic artery, and transcervical insonation of the extracranial ICA. Repeated exams were performed in cases of persistent diastolic flow.

Results: The specificity of the testing was 100%, no false-positive cases were recorded. The sensitivity of conventional TCD examination was 82.1%. The insonation of the extracranial ICA increased sensitivity to 88% allowing the detection of CCA in those patients lacking temporal windows; serial examinations further increased sensitivity to 95.6%.

Conclusions: The addition of insonation of the cervical ICA and of the siphon increased sensitivity of TCD. Nevertheless, a CCA flow patterns may appear later on those segments. Serial examinations, may be needed in those cases.

PubMed Disclaimer

References

    1. J Neurol Sci. 2003 Jun 15;210(1-2):31-4 - PubMed
    1. J Neurol Sci. 1998 Aug 14;159(2):145-50 - PubMed
    1. Neurosurgery. 1988 Apr;22(4):654-61 - PubMed
    1. Intensive Care Med. 1995 Aug;21(8):657-62 - PubMed
    1. Intensive Care Med. 1999 Aug;25(8):822-8 - PubMed

MeSH terms

LinkOut - more resources