Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Mar;250(3):784-92.
doi: 10.1148/radiol.2503080874.

Myometrial invasion in endometrial cancer: diagnostic accuracy of diffusion-weighted 3.0-T MR imaging--initial experience

Affiliations

Myometrial invasion in endometrial cancer: diagnostic accuracy of diffusion-weighted 3.0-T MR imaging--initial experience

Gigin Lin et al. Radiology. 2009 Mar.

Abstract

Purpose: To assess the diagnostic accuracy of fused T2-weighted and high-b-value diffusion-weighted (DW) magnetic resonance (MR) images at 3 T for evaluation of myometrial invasion in patients with endometrial cancer.

Materials and methods: Institutional review board approval and informed consent were obtained. From May 2006 to October 2007, 48 consecutive patients aged 25-80 years (mean age, 57 years) who had endometrial cancer were prospectively enrolled for preoperative evaluation by using a 3-T MR unit. Two radiologists interpreted the depth of myometrial invasion on T2-weighted images, dynamic contrast material-enhanced MR images, and fused T2-weighted and DW MR images (b = 1000 sec/mm(2)). Statistical methods included kappa statistics for reader agreement, Pearson analysis for pathologic correlation, accuracy assessment, and receiver operating characteristic analysis for diagnostic performance comparison. Surgical pathologic findings were the reference standard.

Results: Reader agreement was excellent for fused T2-weighted and DW images (weighted kappa, 0.79), with a significant pathologic correlation regarding the depth of myometrial invasion (r = 0.94, P < .0001). For assessing any myometrial involvement, addition of fused T2-weighted and DW imaging to dynamic contrast-enhanced or dynamic contrast-enhanced and T2-weighted imaging was significantly better compared with dynamic contrast-enhanced imaging alone (P < .001) or dynamic contrast-enhanced and T2-weighted (P = .001) imaging; T2-weighted imaging combined with fused T2-weighted and DW imaging also was better than dynamic contrast-enhanced and T2-weighted imaging (P = .001). Tumor apparent diffusion coefficients were 0.60-1.32 x 10(-3) mm(2)/sec (median, 0.75 x 10(-3) mm(2)/sec), with no significant correlation with the depth of myometrial invasion (P = .31, r = -0.15).

Conclusion: Fused T2-weighted and high-b-value DW images at 3 T can provide accurate information for preoperative evaluation of myometrial invasion.

PubMed Disclaimer

Publication types

LinkOut - more resources