Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Mar;28(3):285-91.
doi: 10.7863/jum.2009.28.3.285.

Gynecologic imaging reporting and data system: a new proposal for classifying adnexal masses on the basis of sonographic findings

Affiliations

Gynecologic imaging reporting and data system: a new proposal for classifying adnexal masses on the basis of sonographic findings

Fernando Amor et al. J Ultrasound Med. 2009 Mar.

Abstract

Objective: The purpose of this study was to describe a new reporting system called the Gynecologic Imaging Reporting and Data System (GI-RADS) for reporting findings in adnexal masses based on transvaginal sonography.

Methods: A total of 171 women (mean age, 39 years; range, 16-77 years) suspected of having an adnexal mass were evaluated by transvaginal sonography before treatment. Pattern recognition analysis and color Doppler blood flow location were used for determining the presumptive diagnosis. Then the GI-RADS was used, with the following classifications: GI-RADS 1, definitively benign; GI-RADS 2, very probably benign; GI-RADS 3, probably benign; GI-RADS 4, probably malignant; and GI-RADS 5, very probably malignant. Patients with GI-RADS 1 and 2 tumors were treated expectantly. All GI-RADS 3, 4, and 5 tumors were removed surgically, and a definitive histologic diagnosis was obtained. The GI-RADS classification was compared with final histologic diagnosis.

Results: A total of 187 masses were evaluated. The prevalence rate for malignant tumors was 13.4%. Overall GI-RADS classification rates were as follows: GI-RADS 1, 4 cases (2.1%); GI-RADS 2, 52 cases (27.8%); GI-RADS 3, 90 cases (48.1%); GI-RADS 4, 13 cases (7%); and GI-RADS 5, 28 cases (15%). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 92%, 97%, 85%, 99%, and 96%, respectively.

Conclusions: Our proposed reporting system showed good diagnostic performance. It is simple and could facilitate communication between sonographers/sonologists and clinicians.