LASIK for hyperopic astigmatism and presbyopia using micro-monovision with the Carl Zeiss Meditec MEL80 platform
- PMID: 19244952
- DOI: 10.3928/1081597X-20090101-07
LASIK for hyperopic astigmatism and presbyopia using micro-monovision with the Carl Zeiss Meditec MEL80 platform
Abstract
Purpose: To evaluate the monocular and binocular outcomes of LASIK for a micro-monovision protocol for the correction of hyperopic astigmatism and presbyopia.
Methods: A prospective non-comparative case series included 258 eyes of 129 consecutive patients with hyperopic astigmatism and presbyopia who were treated with LASIK-induced micro-monovision. The CRS-Master software was used to generate ablation profiles for the Carl Zeiss Meditec MEL80 excimer laser. The target refraction was piano for distance eyes (dominant eye) and between -1.00 and -1.50 diopters (D) for near eyes. Patients were followed for 1 year.
Results: Mean attempted spherical equivalent refraction (SE) correction was +2.54+/-1.16 D (range: +0.25 to +5.75 D). Mean attempted cylinder was -0.52+/-0.49 D (range: -0.00 to -3.25 D). Median age was 56 years (range: 44 to 66 years). Median follow-up was 12.5 months (range: 3.3 months [early retreatment] to 18.2 months). The retreatment rate was 22%. Outcome measures after all treatments were as follows. Mean deviation from the intended SE correction was +0.09+/-0.48 D, with 79% of eyes within +/-0.50 D and 95% within +/-1.00 D. The cylinder correction ratio was 1.23+/-0.63 and the error ratio was 0.67+/-0.65. Of the distance eyes, 86% achieved uncorrected visual acuity of 20/20 and 100% achieved 20/40. Binocularly, 95% of patients achieved 20/20 and 100% achieved 20/40. Eighty-one percent of patients could read J2 and 100% could read J5. Binocularly, 95% of patients achieved 20/20 and could read J5. No eyes lost 2 or more lines of best spectacle-corrected visual acuity. A statistically significant increase was noted in contrast sensitivity at 3 and 6 cycles per degree (cpd), with no reduction at 12 and 18 cpd. The average change in refraction between 3 months and 1 year was +0.11+/-0.36 D with a change of >1.00 D in 2.6% of eyes.
Conclusions: This hyperopic micro-monovision protocol was a well-tolerated and effective procedure for treating patients with presbyopia in moderate to high hyperopia with corrections ranging up to +5.75 D. Contrast sensitivity was improved and the distance vision of near eyes was found to contribute positively to binocular distance vision compared to distance eyes monocularly.
Similar articles
-
LASIK for presbyopia correction in emmetropic patients using aspheric ablation profiles and a micro-monovision protocol with the Carl Zeiss Meditec MEL 80 and VisuMax.J Refract Surg. 2012 Aug;28(8):531-41. doi: 10.3928/1081597X-20120723-01. J Refract Surg. 2012. PMID: 22869232
-
Outcomes of Corneal Compound Hyperopic Astigmatism With Presbyopia by Zeiss PRESBYOND Laser Blended Vision LASIK Using Default Custom Refractive Software Master Target Refractions for Reduced Anisometropia.J Refract Surg. 2024 Jul;40(7):e480-e489. doi: 10.3928/1081597X-20240506-02. Epub 2024 Jul 1. J Refract Surg. 2024. PMID: 39007817
-
Aspheric Micro-monovision LASIK in Correction of Presbyopia and Myopic Astigmatism: Early Clinical Outcomes in a Chinese Population.J Refract Surg. 2016 Oct 1;32(10):680-685. doi: 10.3928/1081597X-20160628-01. J Refract Surg. 2016. PMID: 27722755
-
Presbyopic Excimer Laser Ablation: A Review.J Refract Surg. 2018 Oct 1;34(10):698-710. doi: 10.3928/1081597X-20180726-02. J Refract Surg. 2018. PMID: 30296331 Review.
-
Laser refractive correction of presbyopia.Indian J Ophthalmol. 2024 Sep 1;72(9):1236-1243. doi: 10.4103/IJO.IJO_3074_23. Epub 2024 Aug 23. Indian J Ophthalmol. 2024. PMID: 39185826 Free PMC article. Review.
Cited by
-
Review of Static Approaches to Surgical Correction of Presbyopia.J Ophthalmic Vis Res. 2017 Oct-Dec;12(4):413-418. doi: 10.4103/jovr.jovr_162_16. J Ophthalmic Vis Res. 2017. PMID: 29090052 Free PMC article. Review.
-
Supracor Multifocal Corneal Laser-Assisted In Situ Keratomileusis Procedure for the Correction of Presbyopia in Hyperopic Eyes.J Curr Ophthalmol. 2023 Dec 21;35(2):165-169. doi: 10.4103/joco.joco_2_23. eCollection 2023 Apr-Jun. J Curr Ophthalmol. 2023. PMID: 38250484 Free PMC article.
-
Outcomes of Corneal Compound Myopic Astigmatism with Presbyopia by Zeiss PRESBYOND® Laser Blended Vision LASIK Using Default CRS-Master® Target Refractions for Reduced Anisometropia.J Clin Med. 2024 May 20;13(10):3011. doi: 10.3390/jcm13103011. J Clin Med. 2024. PMID: 38792550 Free PMC article.
-
Artemis very high frequency digital ultrasound-guided femtosecond laser recut after flap complication.Digit J Ophthalmol. 2014 Sep 14;20(3):43-57. doi: 10.5693/djo.02.2014.01.003. eCollection 2014. Digit J Ophthalmol. 2014. PMID: 27843416 Free PMC article.
-
Functional Outcomes and Reading Speeds following PRESBYOND LBV Using Nonlinear Aspheric Ablation Profiles Combined with Micro-Monovision.J Ophthalmol. 2021 Jul 31;2021:2957443. doi: 10.1155/2021/2957443. eCollection 2021. J Ophthalmol. 2021. PMID: 34381620 Free PMC article.