Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Mar 3;53(9):765-73.
doi: 10.1016/j.jacc.2008.11.024.

Insights from a cardiac resynchronization optimization clinic as part of a heart failure disease management program

Affiliations
Free article

Insights from a cardiac resynchronization optimization clinic as part of a heart failure disease management program

Wilfried Mullens et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: Our aim was to determine the feasibility and value of a protocol-driven approach to patients with cardiac resynchronization therapy (CRT) who did not exhibit a positive response long after implant.

Background: Up to one-third of patients with advanced heart failure do not exhibit a positive response to CRT.

Methods: A total of 75 consecutive ambulatory patients with persistent advanced heart failure symptoms and/or adverse reverse remodeling and CRT implanted >6 months underwent a comprehensive protocol-driven evaluation to determine the potential reasons for a suboptimal response. Recommendations were made to maximize the potential of CRT, and adverse events were documented.

Results: All patients (mean left ventricular [LV] ejection fraction 23 +/- 9%, LV end-diastolic volume 275 +/- 127 ml) underwent evaluation. Eighty-eight percent of patients had significantly better echocardiographic indexes of LV filling and LV ejection with optimal setting of their CRT compared with a temporary VVI back-up setting. Most patients had identifiable reasons for suboptimal response, including inadequate device settings (47%), suboptimal medical treatment (32%), arrhythmias (32%), inappropriate lead position (21%), or lack of baseline dyssynchrony (9%). Multidisciplinary recommendations led to changes in device settings and/or other therapy modifications in 74% of patients and were associated with fewer adverse events (13% vs. 50%, odds ratio: 0.2 [95% confidence interval: 0.07 to 0.56], p = 0.002) compared with those in which no recommendation could be made.

Conclusions: Routine protocol-driven approach to evaluate ambulatory CRT patients who did not exhibit a positive response is feasible, and changes in device settings and/or other therapies after multidisciplinary evaluation may be associated with fewer adverse events.