Clinical application of hepatic CT perfusion
- PMID: 19248188
- PMCID: PMC2653413
- DOI: 10.3748/wjg.15.907
Clinical application of hepatic CT perfusion
Abstract
Complicated changes occur in hemodynamics of hepatic artery and vein, and portal vein under various kinds of pathologic status because of distinct double hepatic blood supply. This article reviews the clinical application of hepatic x-ray computed tomography perfusion in some liver diseases.
Figures


Similar articles
-
Dynamic helical CT as a novel technique for diagnosing hepatic perfusion disorders.Hepatogastroenterology. 1999 Jan-Feb;46(25):303-7. Hepatogastroenterology. 1999. PMID: 10228812
-
Hepatic Sinusoidal Dilatation: A Review of Causes With Imaging-Pathologic Correlation.Semin Ultrasound CT MR. 2016 Dec;37(6):525-532. doi: 10.1053/j.sult.2016.08.007. Epub 2016 Aug 17. Semin Ultrasound CT MR. 2016. PMID: 27986171 Review.
-
Physiologic and pathophysiologic aspects of the hepatic hemodynamics.Prog Liver Dis. 1972;4:201-16. Prog Liver Dis. 1972. PMID: 4568997 Review. No abstract available.
-
The hepatic venous system. Its pathologic roentgen anatomy.Radiology. 1968 Jun;90(6):1124-31. doi: 10.1148/90.6.1124. Radiology. 1968. PMID: 5656732 No abstract available.
-
Hepatic abnormalities related to blood flow: evaluation with dual-phase helical CT.Abdom Imaging. 1999 Jul-Aug;24(4):340-56. doi: 10.1007/s002619900512. Abdom Imaging. 1999. PMID: 10390555 Review. No abstract available.
Cited by
-
The evaluation of haemodynamics in cirrhotic patients with spectral CT.Br J Radiol. 2013 Aug;86(1028):20130228. doi: 10.1259/bjr.20130228. Br J Radiol. 2013. PMID: 23881800 Free PMC article.
-
Abdominal perfusion computed tomography.Eurasian J Med. 2013 Feb;45(1):50-7. doi: 10.5152/eajm.2013.09. Eurasian J Med. 2013. PMID: 25610249 Free PMC article. Review.
-
Role of Perfusion CT Differentiating Hemangiomas from Malignant Hepatic Lesions.J Clin Imaging Sci. 2014 Feb 27;4:10. doi: 10.4103/2156-7514.127959. eCollection 2014. J Clin Imaging Sci. 2014. PMID: 24744967 Free PMC article.
-
Stereological quantification of microvessels using semiautomated evaluation of X-ray microtomography of hepatic vascular corrosion casts.Int J Comput Assist Radiol Surg. 2016 Oct;11(10):1803-19. doi: 10.1007/s11548-016-1378-3. Epub 2016 Mar 23. Int J Comput Assist Radiol Surg. 2016. PMID: 27008472
-
Fat Quantification Imaging and Biophysical Modeling for Patient-Specific Forecasting of Microwave Ablation Therapy.Front Physiol. 2022 Feb 3;12:820251. doi: 10.3389/fphys.2021.820251. eCollection 2021. Front Physiol. 2022. PMID: 35185606 Free PMC article.
References
-
- Miles KA, Hayball M, Dixon AK. Colour perfusion imaging: a new application of computed tomography. Lancet. 1991;337:643–645. - PubMed
-
- Miles KA, Hayball MP, Dixon AK. Functional images of hepatic perfusion obtained with dynamic CT. Radiology. 1993;188:405–411. - PubMed
-
- Blomley MJ, Coulden R, Dawson P, Kormano M, Donlan P, Bufkin C, Lipton MJ. Liver perfusion studied with ultrafast CT. J Comput Assist Tomogr. 1995;19:424–433. - PubMed
-
- Weidekamm C, Cejna M, Kramer L, Peck-Radosavljevic M, Bader TR. Effects of TIPS on liver perfusion measured by dynamic CT. AJR Am J Roentgenol. 2005;184:505–510. - PubMed
-
- Zhou ZF, Huang HL, Xu B, Lin BJ, Liu ZH, Yang JY, Qiu YC. Clinic application with MSCT perfusion in liver tumor. Linchuang Fangshexue Zazhi. 2006;25:233–237.