The effect on minimum tumor dose of restricting target-dose inhomogeneity in optimized three-dimensional treatment of lung cancer
- PMID: 1924862
- DOI: 10.1016/0167-8140(91)90049-m
The effect on minimum tumor dose of restricting target-dose inhomogeneity in optimized three-dimensional treatment of lung cancer
Abstract
An examination was made of the effect upon the minimum tumor dose of a limit placed on the variation of dose across target. If the required level of target dose uniformity is slightly relaxed, a substantial improvement in the minimum tumor dose might appear. It was conjectured that this effect could be seen with treatments optimally planned and evaluated in three-dimensions. A model of advanced carcinoma of the lung treated with a computer controlled accelerator was used to test this hypothesis. A mathematical program for optimizing beam weights was used to determine the largest minimum tumor dose possible. In the six cases tested, a minimum tumor dose of greater than 80 Gy could be delivered if a 20% inhomogeneity limit was accepted. The minimum tumor dose fell to the range 44-64 Gy when the inhomogeneity limit was tightened to 13-17%. The results imply a need to examine the choice of a required level of dose uniformity from the range of values suggested in the 2-dimensional planning literature. If a strict bound-on-dose uniformity is preserved, mechanisms--such as formal optimization--which can reduce target dose inhomogeneity will be valuable.
Similar articles
-
Three-dimensional radiation treatment planning study for patients with carcinoma of the lung.Int J Radiat Oncol Biol Phys. 1994 Jul 30;29(5):1105-17. doi: 10.1016/0360-3016(94)90407-3. Int J Radiat Oncol Biol Phys. 1994. PMID: 8083080
-
Interactively exploring optimized treatment plans.Int J Radiat Oncol Biol Phys. 2005 Feb 1;61(2):570-82. doi: 10.1016/j.ijrobp.2004.09.022. Int J Radiat Oncol Biol Phys. 2005. PMID: 15667980
-
Inhomogeneous target-dose distributions: a dimension more for optimization?Int J Radiat Oncol Biol Phys. 1999 May 1;44(2):461-8. doi: 10.1016/s0360-3016(98)00464-7. Int J Radiat Oncol Biol Phys. 1999. PMID: 10760444
-
Potential for reduced toxicity and dose escalation in the treatment of inoperable non-small-cell lung cancer: a comparison of intensity-modulated radiation therapy (IMRT), 3D conformal radiation, and elective nodal irradiation.Int J Radiat Oncol Biol Phys. 2003 Nov 1;57(3):875-90. doi: 10.1016/s0360-3016(03)00743-0. Int J Radiat Oncol Biol Phys. 2003. PMID: 14529795
-
Application of the LQ model to the interpretation of absorbed dose distribution in the daily practice of radiotherapy.Radiother Oncol. 1991 Nov;22(3):180-9. doi: 10.1016/0167-8140(91)90022-9. Radiother Oncol. 1991. PMID: 1771259 Review.
Cited by
-
Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions.Med Phys. 2013 May;40(5):051708. doi: 10.1118/1.4801897. Med Phys. 2013. PMID: 23635256 Free PMC article.
-
Effectiveness of 125I seed implantation in the treatment of non-small cell lung cancer during R2 resection.Oncol Lett. 2017 Dec;14(6):6690-6700. doi: 10.3892/ol.2017.7019. Epub 2017 Sep 21. Oncol Lett. 2017. PMID: 29163696 Free PMC article.
-
CT-guided implantation of radioactive 125I seed in advanced non-small-cell lung cancer after failure of first-line chemotherapy.J Cancer Res Clin Oncol. 2014 Aug;140(8):1383-90. doi: 10.1007/s00432-014-1655-x. Epub 2014 Apr 11. J Cancer Res Clin Oncol. 2014. PMID: 24723151 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical