Protein deposition on a lathe-cut silicone hydrogel contact lens material
- PMID: 19252421
- DOI: 10.1097/OPX.0b013e3181981b54
Protein deposition on a lathe-cut silicone hydrogel contact lens material
Abstract
Purpose: To determine the quantity of total protein, total lysozyme, and the conformational state of lysozyme deposited on a novel, lathe-cut silicone hydrogel (SiHy) contact lens material (sifilcon A) after 3 months of wear.
Methods: Twenty-four subjects completed a prospective, bilateral, daily-wear, 9-month clinical evaluation in which the subjects were fitted with a novel, custom-made, lathe-cut SiHy lens material. The lenses were worn for three consecutive 3-month periods, with lenses being replaced after each period of wear. After 3 months of wear, the lenses from the left eye were collected and assessed for protein analysis. The total protein deposited on the lenses was determined by a modified Bradford assay, total lysozyme using Western blotting and the lysozyme activity was determined using a modified micrococcal assay.
Results: The total protein recovered from the custom-made lenses was 5.3 +/- 2.3 microg/lens and the total lysozyme was 2.4 +/- 1.2 microg/lens. The denatured lysozyme found on the lenses was 1.9 +/- 1.0 microg/lens and the percentage of lysozyme denatured was 80 +/- 10%.
Conclusions: Even after 3 months of wear, the quantity of protein and the conformational state of lysozyme deposited on these novel lens materials was very similar to that found on similar surface-coated SiHy lenses after 2 to 4 weeks of wear. These results indicate that extended use of the sifilcon A material is not deleterious in terms of the quantity and quality of protein deposited on the lens.
Similar articles
-
Ex vivo protein deposition on bi-weekly silicone hydrogel contact lenses.Optom Vis Sci. 2009 Nov;86(11):1241-9. doi: 10.1097/OPX.0b013e3181bbc1b3. Optom Vis Sci. 2009. PMID: 19770811 Clinical Trial.
-
Rewetting drops containing surface active agents improve the clinical performance of silicone hydrogel contact lenses.Optom Vis Sci. 2006 Mar;83(3):143-51. doi: 10.1097/01.opx.0000204513.76568.57. Optom Vis Sci. 2006. PMID: 16534456 Clinical Trial.
-
Quantity and conformation of lysozyme deposited on conventional and silicone hydrogel contact lens materials using an in vitro model.Eye Contact Lens. 2007 May;33(3):138-43. doi: 10.1097/01.icl.0000244155.87409.f6. Eye Contact Lens. 2007. PMID: 17502748
-
An early assessment of silicone hydrogel safety: pearls and pitfalls, and current status.Eye Contact Lens. 2007 Nov;33(6 Pt 2):358-61; discussion 362-3. doi: 10.1097/ICL.0b013e318157c77f. Eye Contact Lens. 2007. PMID: 17975420 Review.
-
Biocompatibility in the development of silicone-hydrogel lenses.Eye Contact Lens. 2013 Jan;39(1):13-9. doi: 10.1097/ICL.0b013e31827dbb00. Eye Contact Lens. 2013. PMID: 23271477 Review.
Cited by
-
Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses.Optom Vis Sci. 2015 Jul;92(7):750-7. doi: 10.1097/OPX.0000000000000615. Optom Vis Sci. 2015. PMID: 26002002 Free PMC article. Review.
-
The efficiency of contact lens care regimens on protein removal from hydrogel and silicone hydrogel lenses.Mol Vis. 2010 Jan 20;16:79-92. Mol Vis. 2010. PMID: 20098668 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources