Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff. Surgical technique
- PMID: 19255195
- DOI: 10.2106/JBJS.H.01426
Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff. Surgical technique
Abstract
Background: It is generally believed that the supraspinatus is the most commonly involved tendon in rotator cuff tears. Clinically, however, atrophy of the infraspinatus muscle is frequently observed in patients with even small to medium-size rotator cuff tears. This fact cannot be fully explained by our current understanding of the anatomical insertions of the supraspinatus and infraspinatus. The purpose of this study was to reinvestigate the humeral insertions of these tendons.
Methods: The study included 113 shoulders from sixty-four cadavers. The humeral insertion areas of the supraspinatus and infraspinatus were investigated in ninety-seven specimens. In sixteen specimens, all muscular portions of the supraspinatus and infraspinatus were removed, leaving the tendinous portions intact, in order to define the specific characteristics of the tendinous portion of the muscles. Another twenty-six shoulders were used to obtain precise measurements of the footprints of the supraspinatus and infraspinatus.
Results: The supraspinatus had a long tendinous portion in the anterior half of the muscle, which always inserted into the anteriormost area of the highest impression on the greater tuberosity and which inserted into the superiormost area of the lesser tuberosity in 21% of the specimens. The footprint of the supraspinatus was triangular in shape, with an average maximum medial-to-lateral length of 6.9 mm and an average maximum anteroposterior width of 12.6 mm. The infraspinatus had a long tendinous portion in the superior half of the muscle, which curved anteriorly and extended to the anterolateral area of the highest impression of the greater tuberosity. The footprint of the infraspinatus was trapezoidal in shape, with an average maximum medial-to-lateral length of 10.2 mm and an average maximum anteroposterior width of 32.7 mm.
Conclusions: The footprint of the supraspinatus on the greater tuberosity is much smaller than previously believed, and this area of the greater tuberosity is actually occupied by a substantial amount of the infraspinatus.
Similar articles
-
Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff.J Bone Joint Surg Am. 2008 May;90(5):962-9. doi: 10.2106/JBJS.G.00427. J Bone Joint Surg Am. 2008. PMID: 18451386
-
Morphology of the humeral insertion of the supraspinatus and infraspinatus tendons: Application to rotator cuff repair.Clin Anat. 2015 Sep;28(6):767-73. doi: 10.1002/ca.22548. Epub 2015 Apr 23. Clin Anat. 2015. PMID: 25914209
-
The superior capsule of the shoulder joint complements the insertion of the rotator cuff.J Shoulder Elbow Surg. 2012 Jul;21(7):867-72. doi: 10.1016/j.jse.2011.04.034. Epub 2011 Aug 4. J Shoulder Elbow Surg. 2012. PMID: 21816631
-
Effect of anterior supraspinatus tendon partial-thickness tears on infraspinatus tendon strain through a range of joint rotation angles.J Shoulder Elbow Surg. 2010 Jun;19(4):617-23. doi: 10.1016/j.jse.2009.10.003. Epub 2010 Jan 15. J Shoulder Elbow Surg. 2010. PMID: 20080051 Free PMC article. Review.
-
The Rotator Cuff and the Superior Capsule: Why We Need Both.Arthroscopy. 2016 Dec;32(12):2628-2637. doi: 10.1016/j.arthro.2016.08.011. Arthroscopy. 2016. PMID: 27916191 Review.
Cited by
-
A histoanatomical study of the fiber bundle forming the 'Comma Sign,' a critical marker of the torn edge of the subscapularis tendon.Arch Orthop Trauma Surg. 2021 Jul;141(7):1231-1239. doi: 10.1007/s00402-021-03775-6. Epub 2021 Jan 17. Arch Orthop Trauma Surg. 2021. PMID: 33454805
-
Classification of rotator cuff tendinopathy using high definition ultrasound.Muscles Ligaments Tendons J. 2014 Nov 17;4(3):391-7. eCollection 2014 Jul. Muscles Ligaments Tendons J. 2014. PMID: 25489559 Free PMC article.
-
Is arthroscopic remplissage a tenodesis or capsulomyodesis? An anatomic study.Knee Surg Sports Traumatol Arthrosc. 2016 Feb;24(2):573-7. doi: 10.1007/s00167-015-3756-8. Epub 2015 Aug 15. Knee Surg Sports Traumatol Arthrosc. 2016. PMID: 26275371
-
Rotator cuff tear patterns: MRI appearance and its surgical relevance.Insights Imaging. 2024 Feb 27;15(1):61. doi: 10.1186/s13244-024-01607-w. Insights Imaging. 2024. PMID: 38411840 Free PMC article. Review.
-
Revisiting the rotator cuff footprint.J Clin Orthop Trauma. 2021 Jul 21;21:101514. doi: 10.1016/j.jcot.2021.101514. eCollection 2021 Oct. J Clin Orthop Trauma. 2021. PMID: 34367915 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical