Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Mar 1;196(2):724-743.
doi: 10.1016/j.amc.2007.07.026.

Deconvolving an Estimate of Breath Measured Blood Alcohol Concentration from Biosensor Collected Transdermal Ethanol Data

Affiliations

Deconvolving an Estimate of Breath Measured Blood Alcohol Concentration from Biosensor Collected Transdermal Ethanol Data

M Dumett et al. Appl Math Comput. .

Abstract

Biosensor measurement of transdermal alcohol oncentration in perspiration exhibits significant variance from subject to subject and device to device. Short duration data collected in a controlled clinical setting is used to calibrate a forward model for ethanol transport from the blood to the sensor. The calibrated model is then used to invert transdermal signals collected in the field (short or long duration) to obtain an estimate for breath measured blood alcohol concentration. A distributed parameter model for the forward transport of ethanol from the blood through the skin and its processing by the sensor is developed. Model calibration is formulated as a nonlinear least squares fit to data. The fit model is then used as part of a spline based scheme in the form of a regularized, non-negatively constrained linear deconvolution. Fully discrete, steepest descent based schemes for solving the resulting optimization problems are developed. The adjoint method is used to accurately and efficiently compute requisite gradients. Efficacy is demonstrated on subject field data.

PubMed Disclaimer

Figures

FIGURE 1.1
FIGURE 1.1
The Giner WrisTAS V.
FIGURE 1.2
FIGURE 1.2
Breath and transdermal data for Subject 1 (left) and Subject 2 (right).
FIGURE 2.1
FIGURE 2.1
Two phase design of the data analysis system (left) and the Blood/Lung/Breath analyzer and Blood/Skin/TAS systems (right).
FIGURE 3.1
FIGURE 3.1
A schematic diagram the Skin and TAS model.
FIGURE 5.1
FIGURE 5.1
The fit of the model to Subject 1’s hospital data (left) and the fit of the model to Subject 2’s hospital data (right).
FIGURE 5.2
FIGURE 5.2
BrAC recovery for Subject 1 (left) and BrAC recovery for Subject 2 (right).
FIGURE 6.1
FIGURE 6.1
Deconvolution of Subject 1’s calibration data (left) and forward simulation of Subject 2’s field test using fit model (right).
FIGURE 6.2
FIGURE 6.2
Forward simulation of Subject 1’s (left) and Subject 2’s (right) field test using recovered and interpolated subject supplied measurements of BrAC.

Similar articles

Cited by

References

    1. Anderson JC, Hlastala MP. The kinetics of transdermal ethanol exchange. J. Appl. Physiol. 2006;100:649–655. - PubMed
    1. Batt RD. Adsorption, distribution and elimination of alcohol. In: Crow KE, Batt RD, editors. Human Metabolism of Alcohol. vol. 1. Boca Raton, FL: CRC Press; 1989.
    1. Banks HT, Ito K. A unified framework for approximation in inverse problems for distributed parameter systems, Control Theory and Advanced Technology. 1988 March;Vol. 4(No 1):73–90.
    1. Banks HT, Kunish K. Estimation techniques for distributed parameter systems, Birkhauser. 1989
    1. Cheung C, Davies NG, Hoog J, Hotchkiss SAM, Smith CK. Species variations in cutaneous alcohol dehydrogenases and aldehyde dehydrogenases may impact on toxicological assessments of alcohols and aldehydes. Toxicology. 2003;184:97–112. - PubMed

LinkOut - more resources