Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2009 Mar;21(3):93-8.

Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis

Affiliations
  • PMID: 19258637
Clinical Trial

Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis

Corrado Tamburino et al. J Invasive Cardiol. 2009 Mar.

Abstract

Background: Percutaneous aortic valve replacement (PAVR) is an emerging alternative for high-risk patients with severe aortic stenosis. The aim of this study was to report acute and short-term outcomes of PAVR with the 18 Fr CoreValve Revalving System.

Methods: From January 2007 to July 2008, 69 high-risk symptomatic patients with severe aortic stenosis were screened to assess their eligibility criteria for PAVR. All candidates were evaluated by a cardiac surgeon and a cardiologist. Thirty patients (13 men, 17 women, ages 82 +/- 5 years, range 73-88 years) met all the eligibility criteria and were enrolled in the study.

Results: Twenty-nine patients (97%) underwent successful valve implantation by a retrograde approach, with improvement in valve area (0.61 +/- 0.18 cm(2) to 1.49 +/- 0.39 cm(2); p < 0.001) and transvalvular gradient (58.1 +/- 17.6 mmHg to 9.2 +/- 4.0; p < 0.001). Paravalvular leakages were 1+ (n = 12) and 2+ (n = 2). Procedural success was achieved in 93% of patients, with 1 case of pericardial tamponade occurred during the first 48 hours after implantation. At 30-day mortality was 7%. The mean NYHA Functional Class declined from 2.72 +/- 0.59 to 1.31 +/- 0.47 (p < 0.001). No other major adverse events occurred at a mean follow up of 4.9 +/- 4.0 months (range 1-13 months).

Conclusions: Our initial experience of PAVR in a cohort of older and high-risk surgical patients has been positive, with excellent acute and encouraging short-term results in terms of safety and efficacy.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources