Autoantibodies to cardiac troponin associate with higher initial concentrations and longer release of troponin I in acute coronary syndrome patients
- PMID: 19264856
- DOI: 10.1373/clinchem.2008.115469
Autoantibodies to cardiac troponin associate with higher initial concentrations and longer release of troponin I in acute coronary syndrome patients
Abstract
Background: Cardiac troponin (cTn) is an established marker of myocardial infarction. Pronounced heterogeneity and the minute amounts released into the circulation constitute significant challenges for cTn detection. Recently, autoantibody formation to cTn was shown to be common and to interfere with immunoassay performance. In this study, we investigated cTn autoantibodies and cardiac troponin I (cTnI) in acute coronary syndrome (ACS) patients over a 1-year period after the index event.
Methods: We used a second-generation cTnI assay designed to reduce the interference of cTn autoantibodies. The assay for cTn autoantibodies used 2 anti-cTnI antibodies to capture the ternary cTnI-complex, enabling unrestricted binding of the autoantibodies, which were detected with a labeled antihuman IgG antibody. We analyzed serum samples from 81 non-ST-elevation ACS patients taken at admission and after 1 week and 3 and 12 months.
Results: We found 14 cTn autoantibody-positive patients (21%) among the 67 cTnI-positive and none among the 14 cTnI-negative patients. Nine were autoantibody-positive at admission, and 5 became positive at 1 week. Autoantibody signals significantly increased in the 1-week and 3-month samples. At all time points, cTnI was significantly increased in the autoantibody-positive group relative to the negative group. Persistent cTnI elevations at 3 and 12 months were seen in the patients already autoantibody positive at admission.
Conclusions: During ACS, patients with cTn autoantibodies have higher cTnI release and therefore larger myocardial damage than patients without autoantibodies. Their cTnI release also lasts longer, at least months. The possible prognostic impact of these observations must be evaluated in larger clinical cohorts.
Similar articles
-
Novel sensitive cardiac troponin I immunoassay free from troponin I-specific autoantibody interference.Clin Chem Lab Med. 2014 Jul;52(7):1041-8. doi: 10.1515/cclm-2013-1044. Clin Chem Lab Med. 2014. PMID: 24615485
-
Troponin-specific autoantibody interference in different cardiac troponin I assay configurations.Clin Chem. 2012 Jun;58(6):1040-8. doi: 10.1373/clinchem.2011.179226. Epub 2012 Apr 9. Clin Chem. 2012. PMID: 22490617
-
Comparison of cardiac troponin I immunoassays variably affected by circulating autoantibodies.Clin Chem. 2005 May;51(5):848-55. doi: 10.1373/clinchem.2004.040089. Epub 2005 Feb 17. Clin Chem. 2005. PMID: 15718488
-
High-sensitivity cardiac troponin assays: From improved analytical performance to enhanced risk stratification.Crit Rev Clin Lab Sci. 2017 May;54(3):143-172. doi: 10.1080/10408363.2017.1285268. Epub 2017 May 1. Crit Rev Clin Lab Sci. 2017. PMID: 28457177 Review.
-
Cardiac troponin after percutaneous coronary intervention and 1-year mortality in non-ST-segment elevation acute coronary syndrome using systematic evaluation of biomarker trends.J Am Coll Cardiol. 2013 Jul 16;62(3):242-251. doi: 10.1016/j.jacc.2013.04.043. Epub 2013 May 15. J Am Coll Cardiol. 2013. PMID: 23684676 Review.
Cited by
-
Point-of-Care Compatibility of Ultra-Sensitive Detection Techniques for the Cardiac Biomarker Troponin I-Challenges and Potential Value.Biosensors (Basel). 2018 Nov 21;8(4):114. doi: 10.3390/bios8040114. Biosensors (Basel). 2018. PMID: 30469415 Free PMC article. Review.
-
Multiple immunoassay systems are negatively interfered by circulating cardiac troponin I autoantibodies.Clin Exp Med. 2012 Mar;12(1):47-53. doi: 10.1007/s10238-011-0141-x. Epub 2011 Jun 8. Clin Exp Med. 2012. PMID: 21655961
-
Anti-PD1 associated fulminant myocarditis after a single pembrolizumab dose: the role of occult pre-existing autoimmunity.Haematologica. 2018 Jul;103(7):e318-e321. doi: 10.3324/haematol.2017.185777. Epub 2018 Apr 12. Haematologica. 2018. PMID: 29650641 Free PMC article. No abstract available.
-
Cardiac troponin I autoantibody induces myocardial dysfunction by PTEN signaling activation.EBioMedicine. 2019 Sep;47:329-340. doi: 10.1016/j.ebiom.2019.08.045. Epub 2019 Aug 29. EBioMedicine. 2019. PMID: 31474552 Free PMC article.
-
Cardiac troponin T quantitative assay failure as a result of antibody interference.Afr J Lab Med. 2013 Dec 3;2(1):23. doi: 10.4102/ajlm.v2i1.23. eCollection 2013. Afr J Lab Med. 2013. PMID: 29043157 Free PMC article.