Dynamic breasts: a common complication following partial submuscular augmentation and its correction using the muscle-splitting biplane technique
- PMID: 19280247
- DOI: 10.1007/s00266-009-9320-5
Dynamic breasts: a common complication following partial submuscular augmentation and its correction using the muscle-splitting biplane technique
Abstract
Background: Dynamic breast deformity following partial submuscular augmentation is not uncommon. The complication is due primarily to the release of the pectoralis and the true incidence of this complication is not known. The submuscular biplane pocket is a new pocket and is used to correct dynamic breasts following augmentation mammaplasty in the partial submuscular plane.
Methods: After the first submuscular biplane muscle-splitting augmentation mammaplasty in October 2005, the author has performed 58 secondary augmentation mammaplasties for various reasons. Of these, nine patients showed marked dynamic breast deformity following partial submuscular augmentation and the submuscular muscle-splitting biplane was used to correct this complication.
Results: Good to excellent results were achieved in all patients with complete elimination of the dynamic breast deformity.
Conclusion: The submuscular biplane is a new and versatile pocket and is used to correct dynamic breast deformity seen following partial submuscular augmentation mammaplasty.
Similar articles
-
Augmentation mastopexy in muscle-splitting biplane: outcome of first 44 consecutive cases of mastopexies in a new pocket.Aesthetic Plast Surg. 2010 Jun;34(3):313-21. doi: 10.1007/s00266-009-9434-9. Epub 2009 Nov 19. Aesthetic Plast Surg. 2010. PMID: 19924469
-
Correction of acquired synmastia with muscle-splitting biplane implant replacement.Aesthetic Plast Surg. 2009 Jul;33(4):605-10. doi: 10.1007/s00266-009-9345-9. Epub 2009 May 5. Aesthetic Plast Surg. 2009. PMID: 19415157
-
Muscle-splitting, subglandular, and partial submuscular augmentation mammoplasties: a 12-year retrospective analysis of 2026 primary cases.Aesthetic Plast Surg. 2013 Apr;37(2):290-302. doi: 10.1007/s00266-012-0026-8. Epub 2013 Jan 26. Aesthetic Plast Surg. 2013. PMID: 23354762
-
Use of the rectus sternalis in augmentation mammoplasty: case report and literature search.Aesthetic Plast Surg. 2008 Jan;32(1):21-4. doi: 10.1007/s00266-007-9046-1. Aesthetic Plast Surg. 2008. PMID: 17965818 Review.
-
Treatment of breast animation deformity: A systematic review.J Plast Reconstr Aesthet Surg. 2019 May;72(5):781-788. doi: 10.1016/j.bjps.2019.02.025. Epub 2019 Mar 5. J Plast Reconstr Aesthet Surg. 2019. PMID: 30902576
Cited by
-
Breast animation deformity.Arch Plast Surg. 2019 Jan;46(1):7-15. doi: 10.5999/aps.2018.00479. Epub 2019 Jan 15. Arch Plast Surg. 2019. PMID: 30685936 Free PMC article.
-
Single-stage Layered versus Nonlayered Mastopexy with Augmentation in Muscle Splitting Biplane: A Comparative Analysis.Plast Reconstr Surg Glob Open. 2022 Sep 23;10(9):e4514. doi: 10.1097/GOX.0000000000004514. eCollection 2022 Sep. Plast Reconstr Surg Glob Open. 2022. PMID: 36168613 Free PMC article.
-
Pectoral Muscle Re-Attachment with Breast Implant Removal.Aesthetic Plast Surg. 2022 Oct;46(5):2614-2617. doi: 10.1007/s00266-022-03011-5. Epub 2022 Jul 20. Aesthetic Plast Surg. 2022. PMID: 35859016
-
Muscle Splitting Augmentation Mastopexy: A l3-year Analysis and Outcome of Primary and Secondary Procedures.Plast Reconstr Surg Glob Open. 2022 Feb 28;10(2):e4138. doi: 10.1097/GOX.0000000000004138. eCollection 2022 Feb. Plast Reconstr Surg Glob Open. 2022. PMID: 35242490 Free PMC article.
-
3D Lipogluing: Preliminary Results of a Novel Technique for Direct Three-dimensional Fat Grafting in Breast Reconstruction Surgery.Plast Reconstr Surg Glob Open. 2024 May 3;12(5):e5788. doi: 10.1097/GOX.0000000000005788. eCollection 2024 May. Plast Reconstr Surg Glob Open. 2024. PMID: 38712016 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical