Diagnostic value of post-bronchodilator pulmonary function testing to distinguish between stable, moderate to severe COPD and asthma
- PMID: 19281083
- PMCID: PMC2650596
- DOI: 10.2147/copd.s948
Diagnostic value of post-bronchodilator pulmonary function testing to distinguish between stable, moderate to severe COPD and asthma
Abstract
Objective: The GOLD guidelines suggest that the presence of a post-bronchodilator forced expiratory volume in one second (FEV1) < 80% of the predicted value in combination with a FEV1/forced vital capacity (FVC) < 70% confirms the diagnosis of COPD. Limited data exist regarding the accuracy of these criteria to distinguish between COPD and asthma. The aim of this study therefore was to investigate the diagnostic value of post-bronchodilator lung function parameters in obstructive lung disease.
Methods: The pulmonary function tests of 43 (22 = COPD, 21 = asthma) patients with similar baseline characteristics were evaluated (baseline FEV were 55.7% +/- 7.6%, and 59.3% +/- 8.4% predicted for COPD and asthma, respectively). Bronchodilator responsiveness (BDR) was calculated according to three recognized pulmonary function test criteria.
Results: The first criteria, post-bronchodilator FEV1 < 80% of the predicted value in combination with a post-bronchodilator FEV1/FVC ratio of < 70%, had an accuracy of 70% to diagnose COPD. This combination was very sensitive (100%) in diagnosing COPD, but it was not specific (38%). The second BDR criteria, defined as an increase of < 12% and 200 mL of initial FEV1 and criterion number 3, an increase of < 9% of predicted FEV1, were less sensitive (55% and 59%, respectively), but more specific (81% and 76% respectively) to diagnose COPD. Our findings suggest that the current recommended spirometric indices are not optimal in differentiating between COPD and asthma.
Figures
) and FEV1/FVC ratio (
) with horizontal bars indicating confidence limits for means at 95% confidence interval.
) and as an increase percentage from the predicted FEV1 (
). Horizontal bars indicate confidence limits for means at 95% confidence interval.References
-
- American Thoracic Society. Lung function testing: selection of reference values and interpretative strategies. Am Rev Respir Dis. 1991;144:1202–18. - PubMed
-
- American Thoracic Society. Standardization of spirometry: 1994 update. Am J Respir Crit Care Med. 1994;152:1107–36. - PubMed
-
- Bumbacea D, Campbell D, Nguyen L, et al. Parameters associated with persistent airflow obstruction in chronic severe asthma. Eur Respir J. 2004;24:122–8. - PubMed