Objectives: The primary objective of this study was to analyze perioperative intra-aortic balloon pump (IABP) insertion in patients undergoing cardiac surgery in the authors' institution from 1995 to 2005 and to propose an explanation for changes in use over this period. A secondary objective was to assess patient variables associated with IABP use.
Design: This is a retrospective study including patients who underwent cardiac surgery between 1995 and 2005.
Setting: The Cardiothoracic Anesthesia Patient Registry of a single teaching institution was queried to obtain the required information.
Participants: Thirty thousand two hundred sixty-nine cardiac surgery patients.
Interventions: Intra-aortic balloon pump insertion before surgery, after cardiopulmonary bypass, or in the cardiovascular intensive care unit was assessed in patients who underwent isolated coronary artery bypass graft surgery, valve surgery, or both. Select patient variables were analyzed for their association with IABP insertion. Transesophageal echocardiography (TEE) examinations, milrinone use, and mortality rates also were determined.
Measurements and main results: Among 30,269 cardiac surgery patients, 1,310 (4.32%) underwent IABP insertion. Combined preoperative, intraoperative, and postoperative IABP use decreased from 7.8% in 1995 to 3.0% in 2005. Simultaneously, the intraoperative use of milrinone increased from 4.8% to 8.8% and postoperative use increased from 5.2% to 7.8%. The number of intraoperative TEE examinations more than doubled from approximately 1,700 to 3,500. The overall mortality for patients with preoperative, intraoperative, and postoperative IABP insertion was 12.6%, 17.5%, and 47.7%, respectively.
Conclusions: From 1995 to 2005, preoperative, intraoperative, and postoperative IABP use decreased by approximately 60% in cardiac surgery patients. Simultaneously, the use of TEE and milrinone each doubled. Although a cause-effect relationship cannot be established from the present study's observational data, the trends coincide and may be related.
Similar articles
-
EuroSCORE directed intraaortic balloon pump placement in high-risk patients undergoing cardiac surgery--retrospective analysis of 267 patients.Interact Cardiovasc Thorac Surg. 2008 May;7(3):389-95. doi: 10.1510/icvts.2007.165795. Epub 2008 Feb 6. Interact Cardiovasc Thorac Surg. 2008. PMID: 18256116
-
Effectiveness of intraaortic balloon pumping in patients who were not able to be weaned from cardiopulmonary bypass after coronary artery bypass surgery and mortality predictors in the perioperative and early postoperative period.Anadolu Kardiyol Derg. 2003 Jun;3(2):124-8. Anadolu Kardiyol Derg. 2003. PMID: 12826506
-
Beneficial effect of preventative intra-aortic balloon pumping in high-risk patients undergoing first-time coronary artery bypass grafting-a single center experience.Artif Organs. 2009 Aug;33(8):587-92. doi: 10.1111/j.1525-1594.2009.00788.x. Epub 2009 Jun 28. Artif Organs. 2009. PMID: 19624583
-
Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass surgery: a meta-analysis of randomized controlled trials.Coron Artery Dis. 2012 Nov;23(7):480-6. doi: 10.1097/MCA.0b013e328358784d. Coron Artery Dis. 2012. PMID: 22954753 Review.
-
Preoperative intra-aortic counterpulsation in high-risk patients undergoing cardiac surgery: a meta-analysis of randomized controlled trials†.Eur J Cardiothorac Surg. 2016 Jan;49(1):5-17. doi: 10.1093/ejcts/ezv258. Epub 2015 Aug 5. Eur J Cardiothorac Surg. 2016. PMID: 26245629 Review.
Cited by
-
Temporal trends in the use of intraaortic balloon pump associated with percutaneous coronary intervention in the United States, 1998-2008.Am Heart J. 2014 Sep;168(3):363-373.e12. doi: 10.1016/j.ahj.2014.02.015. Epub 2014 Jun 6. Am Heart J. 2014. PMID: 25173549 Free PMC article.
-
Outcomes and risk factors associated with in-hospital mortality in patients undergoing coronary artery bypass grafting with low ejection fraction.Front Cardiovasc Med. 2025 Feb 13;11:1513149. doi: 10.3389/fcvm.2024.1513149. eCollection 2024. Front Cardiovasc Med. 2025. PMID: 40017902 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical