Properties of implanted electrodes for functional electrical stimulation
Abstract
Implanted wire electrodes are increasingly being used for the functional electrical stimulation of muscles in partially paralysed patients, yet many of their basic characteristics are poorly understood. In this study we investigated the selectivity, recruitment characteristics and range of control of several types of electrode in triceps surae and plantaris muscles of anaesthetized cats. We found that nerve cuffs are more efficient and selective (i.e., cause less stimulus spread to surrounding muscles) than intramuscular electrodes. Bipolar intramuscular stimulation was more efficient and selective than monopolar stimulation, but only if the nerve entry point was between the electrodes. Monopolar electrodes are efficient and selective if located close to the nerve entry point, but their performance declines with distance from it. Nonetheless, for a variety of reasons monopolar stimulation provides the best compromise in many current applications. Short duration pulses offer the best efficiency (least charge per pulse to elicit force) but high peak currents, increasing the risk of electrode corrosion and tissue damage. Electrode size has little effect on recruitment and should therefore be maximised because this minimises current density.
Similar articles
-
Chronic electrical stimulation of the auditory nerve at high stimulus rates: a physiological and histopathological study.Hear Res. 1997 Mar;105(1-2):1-29. doi: 10.1016/s0378-5955(96)00193-1. Hear Res. 1997. PMID: 9083801
-
Recruitment properties of monopolar and bipolar epimysial electrodes.Ann Biomed Eng. 1986;14(1):53-66. doi: 10.1007/BF02364648. Ann Biomed Eng. 1986. PMID: 3706855
-
Characterization of motor nerve stimulation using sinusoidal low frequency alternating currents and cuff electrodes.J Neural Eng. 2025 Feb 11;22(1). doi: 10.1088/1741-2552/adafdc. J Neural Eng. 2025. PMID: 39879650
-
Selective electrical interfaces with the nervous system.Annu Rev Biomed Eng. 2002;4:407-52. doi: 10.1146/annurev.bioeng.4.020702.153427. Epub 2002 Mar 22. Annu Rev Biomed Eng. 2002. PMID: 12117764 Review.
-
Characteristics of the metal-tissue interface of stimulation electrodes.IEEE Trans Biomed Eng. 1976 Jul;23(4):274-80. doi: 10.1109/tbme.1976.324585. IEEE Trans Biomed Eng. 1976. PMID: 776814 Review. No abstract available.
Cited by
-
In vitro neuronal depolarization and increased synaptic activity induced by infrared neural stimulation.Biomed Opt Express. 2016 Aug 3;7(9):3211-3219. doi: 10.1364/BOE.7.003211. eCollection 2016 Sep 1. Biomed Opt Express. 2016. PMID: 27699093 Free PMC article.
-
Impaired inhibitory reno-renal reflex responses in chronic kidney disease.Front Physiol. 2025 Apr 9;16:1544592. doi: 10.3389/fphys.2025.1544592. eCollection 2025. Front Physiol. 2025. PMID: 40271214 Free PMC article.
-
Tumor prevention facilitates delayed transplant of stem cell-derived motoneurons.Ann Clin Transl Neurol. 2016 Jul 1;3(8):637-49. doi: 10.1002/acn3.327. eCollection 2016 Aug. Ann Clin Transl Neurol. 2016. PMID: 27606345 Free PMC article.
-
Pulsed laser versus electrical energy for peripheral nerve stimulation.J Neurosci Methods. 2007 Jul 30;163(2):326-37. doi: 10.1016/j.jneumeth.2007.03.016. Epub 2007 Mar 31. J Neurosci Methods. 2007. PMID: 17537515 Free PMC article.
-
Properties of electrically evoked potentials activated by optic nerve stimulation with penetrating electrodes of different modes in rabbits.Graefes Arch Clin Exp Ophthalmol. 2015 Dec;253(12):2171-80. doi: 10.1007/s00417-015-3121-0. Epub 2015 Jul 31. Graefes Arch Clin Exp Ophthalmol. 2015. PMID: 26228440
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Medical
Miscellaneous