Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Jan-Feb;43(1):1-6.
doi: 10.3944/AOTT.2009.001.

[Correction of complex lower extremity deformities with the use of the Ilizarov-Taylor spatial frame]

[Article in Turkish]
Affiliations
Free article

[Correction of complex lower extremity deformities with the use of the Ilizarov-Taylor spatial frame]

[Article in Turkish]
Metin Küçükkaya et al. Acta Orthop Traumatol Turc. 2009 Jan-Feb.
Free article

Abstract

Objectives: We evaluated the effectiveness of the Taylor spatial frame (Smith & Nephew, Memphis, TN, USA) in the treatment of complex lower extremity deformities.

Methods: The Taylor spatial frame (TSF) was applied to 29 bone segments of 25 patients (12 females, 13 males; mean age 17 years). Indications for the TSF were congenital disorders (n=12), rickets (n=6), physeal injuries (n=4), stiff nonunions (n=3), malunions (n=3), and sequela from septic arthritis of the knee (n=1). Applications involved the tibia (n=15), femur (n=9), foot (n=4), and knee (n=1) with (n=24) or without (n=5) osteotomies. Following acute correction with the use of the TSF and internal osteosynthesis by plating or nailing, the fixator was removed in six cases. The chronic mode was used in six cases who underwent acute correction. The remaining deformities were gradually corrected using the "total residual mode". The follow-up period ranged from eight months to 42 months (mean 29 months).

Results: The mean duration of external fixator was 24.5 weeks (range 18 to 37 weeks) in 13 tibial and five femoral segments. In all cases, correction was applied until the mechanical axis reached normal limits. Complete consolidation was achieved in all osteotomized segments, including three cases of nonunion. A plantigrade foot was obtained in all foot deformities. Recurrence was seen in one case in which knee contracture and subluxation were treated with soft tissue distraction without osteotomy.

Conclusion: The Taylor spatial frame is a safe and practical method with excellent results in the treatment of nonunions and deformities complicated especially by translation and rotation providing correct clinical data are derived and used.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources