Brain tumor enhancement in magnetic resonance imaging at 3 tesla: intraindividual comparison of two high relaxivity macromolecular contrast media with a standard extracellular gd-chelate in a rat brain tumor model
- PMID: 19300099
- DOI: 10.1097/RLI.0b013e31819817ff
Brain tumor enhancement in magnetic resonance imaging at 3 tesla: intraindividual comparison of two high relaxivity macromolecular contrast media with a standard extracellular gd-chelate in a rat brain tumor model
Abstract
Objectives: The aim of this study was to evaluate lesion enhancement (LE) and contrast-to-noise ratio (CNR) properties of P846, a new intermediate sized, high relaxivity Gd-based contrast agent at 3 Tesla in a rat brain glioma model, and to compare this contrast agent with a high relaxivity, macromolecular compound (P792), and a standard extracellular Gd-chelate (Gd-DOTA).
Materials and methods: Seven rats with experimental induced brain glioma were evaluated using 3 different contrast agents, with each MR examination separated by at least 24 hours. The time between injections assured sufficient clearance of the agent from the tumor, before the next examination. P792 (Gadomelitol, Guerbet, France) and P846 (a new compound from Guerbet Research) are macromolecular and high relaxivity contrast agents with no protein binding, and were compared with the extracellular agent Gd-DOTA (Dotarem, Guerbet, France). T1w gradient echo sequences (TR/TE 200 milliseconds/7.38 milliseconds, flip angle = 90 degrees , acquisition time: 1:42 minutes:sec, voxel size: 0.2 x 0.2 x 2.0 mm, FOV = 40 mm, acquisition matrix: 256 x 256) were acquired before and at 5 consecutive time points after each intravenous contrast injection in the identical slice orientation, using a dedicated 4-channel head array animal coil. The order of contrast media injection was randomized, with however Gd-DOTA used either as the first or second contrast agent. Contrast agent dose was adjusted to compensate for the different T1 relaxivities of the 3 agents. Signal-to-noise ratio, CNR, and LE were evaluated using region-of-interest analysis. A veterinary histopathologist confirmed the presence of a glioma in each subject, after completion of the imaging study.
Results: P792 showed significantly less LE as compared with Gd-DOTA within the first 7 minutes after contrast agent injection (P < 0.05) with, however, reaching comparable LE values at 9 minutes after injection (P = 0.07). However, P792 provided significantly less CNR as compared with Gd-DOTA (P < 0.05) for all examination time points. P846 provided comparable but persistent LE as compared with Gd-DOTA (P < 0.05) and demonstrated significantly greater LE and CNR when compared with P792 (P < 0.05). No statistically significant differences between CNR values for Gd-DOTA and P846 were noted for all examination time points (P < 0.05), with P846 administered at one-fourth the dose as compared with Gd-DOTA.
Conclusion: The intravascular contrast medium P792 showed significantly less LE and CNR in comparison to Gd-DOTA and P846, suggesting that it does not show marked extravasation from tumor neocapillaries and does not significantly cross the disrupted blood brain-barrier in this rat glioma model. In distinction, P846 provides comparable enhancement properties at a field strength of 3 Tesla to the extracellular contrast agent Gd-DOTA, using the adjusted dose, suggesting that it crosses the disrupted blood-brain-barrier and tumor capillaries, most likely based on the decreased molecular weight as compared with P792. At the same time, the high relaxivity of this compound allows for decreasing the injected gadolinium dose by a factor of 4 whereas providing comparable enhancement properties when compared with a standard extracellular Gd-chelate (Gd-DOTA) at a dose of 0.1 mmol/kg body weight.
Similar articles
-
The efficacy of gadobenate dimeglumine (Gd-BOPTA) at 3 Tesla in brain magnetic resonance imaging: comparison to 1.5 Tesla and a standard gadolinium chelate using a rat brain tumor model.Invest Radiol. 2006 Mar;41(3):244-8. doi: 10.1097/01.rli.0000191332.24773.e7. Invest Radiol. 2006. PMID: 16481906
-
Brain tumor enhancement in magnetic resonance imaging: dependency on the level of protein binding of applied contrast agents.Invest Radiol. 2009 Feb;44(2):89-94. doi: 10.1097/RLI.0b013e318191a334. Invest Radiol. 2009. PMID: 19077910
-
Enhancing lesions of the brain: intraindividual crossover comparison of contrast enhancement after gadobenate dimeglumine versus established gadolinium comparators.Acad Radiol. 2006 Jun;13(6):744-51. doi: 10.1016/j.acra.2006.02.056. Acad Radiol. 2006. PMID: 16679277 Clinical Trial.
-
Extracellular gadolinium-based contrast media: differences in diagnostic efficacy.Eur J Radiol. 2008 May;66(2):168-74. doi: 10.1016/j.ejrad.2008.02.010. Epub 2008 Mar 26. Eur J Radiol. 2008. PMID: 18372137 Review.
-
MR angiography of the carotid arteries and intracranial circulation: advantage of a high relaxivity contrast agent.Neuroradiology. 2006 Apr;48 Suppl 1:9-17. doi: 10.1007/s00234-006-1464-2. Neuroradiology. 2006. PMID: 16699848 Review.
Cited by
-
Dynamic study of blood-brain barrier closure after its disruption using ultrasound: a quantitative analysis.J Cereb Blood Flow Metab. 2012 Oct;32(10):1948-58. doi: 10.1038/jcbfm.2012.100. Epub 2012 Jul 18. J Cereb Blood Flow Metab. 2012. PMID: 22805875 Free PMC article.
-
Dynamic Contrast-Enhanced MRI Using a Macromolecular MR Contrast Agent (P792): Evaluation of Antivascular Drug Effect in a Rabbit VX2 Liver Tumor Model.Korean J Radiol. 2015 Sep-Oct;16(5):1029-37. doi: 10.3348/kjr.2015.16.5.1029. Epub 2015 Aug 21. Korean J Radiol. 2015. PMID: 26357497 Free PMC article.
-
High-relaxivity contrast-enhanced magnetic resonance neuroimaging: a review.Eur Radiol. 2010 Oct;20(10):2461-74. doi: 10.1007/s00330-010-1805-8. Epub 2010 Jun 23. Eur Radiol. 2010. PMID: 20567832 Review.
-
A new ex vivo method to evaluate the performance of candidate MRI contrast agents: a proof-of-concept study.J Nanobiotechnology. 2014 Apr 5;12:12. doi: 10.1186/1477-3155-12-12. J Nanobiotechnology. 2014. PMID: 24708566 Free PMC article.
-
A quantitative comparison of the influence of individual versus population-derived vascular input functions on dynamic contrast enhanced-MRI in small animals.Magn Reson Med. 2012 Jan;67(1):226-36. doi: 10.1002/mrm.22988. Epub 2011 Jun 17. Magn Reson Med. 2012. PMID: 21688316 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical