Abstract
A complete mass spectrum was measured at an acquisition rate of 1 kHz using a femtosecond-multiphoton-ionization time-of-flight mass spectrometer for analyte eluting from a gas chromatograph. A contour-map display, i.e. a two-dimensional plot, of the data was first constructed for a simultaneous overview of the mass spectra and the mass chromatograms. The noise component in the signal was then reduced by digital filtering and reduced further by smoothing the data. The detection limit (S/N = 3) was improved from 240 to 76 fg for 2,3,4,6,7-pentachlorodibenzofuran, with no appreciable loss of resolution in the chromatogram. The achieved value was lower than the value (<100 fg) required by Japanese Industrial Standards for dioxin analysis. A new parameter, referred to as a 'reliability factor', was defined in this study to calculate the similarity between the intensity distribution of the isotope peaks observed in the mass spectrum and that calculated from the natural abundance ratio of the isotopes. This parameter was useful for evaluation of the purity of the chromatographic peak.
Similar articles
-
Gas chromatography/femtosecond multiphoton ionization/time-of-flight mass spectrometry of dioxins.Anal Chem. 2010 Aug 1;82(15):6519-25. doi: 10.1021/ac1009063. Anal Chem. 2010. PMID: 20593780
-
Practical considerations in the gas chromatography/combustion/isotope ratio monitoring mass spectrometry of 13C-enriched compounds: detection limits and carryover effects.Rapid Commun Mass Spectrom. 2003;17(23):2669-74. doi: 10.1002/rcm.1230. Rapid Commun Mass Spectrom. 2003. PMID: 14648906
-
Online concentration by analyte adsorption/laser desorption for application to gas chromatography/resonance-enhanced multiphoton ionization time-of-flight mass spectrometry.Anal Chem. 2010 Feb 15;82(4):1283-7. doi: 10.1021/ac902273b. Anal Chem. 2010. PMID: 20085300
-
Factor analysis of hyphenated chromatographic data exploration, resolution and quantification of multicomponent systems.J Chromatogr A. 2007 Jul 27;1158(1-2):184-95. doi: 10.1016/j.chroma.2007.05.045. Epub 2007 May 18. J Chromatogr A. 2007. PMID: 17543980 Review.
-
The isotope distribution: A rose with thorns.Mass Spectrom Rev. 2025 Jan-Feb;44(1):22-42. doi: 10.1002/mas.21820. Epub 2023 Feb 6. Mass Spectrom Rev. 2025. PMID: 36744702 Free PMC article. Review.
Cited by
-
DISCO: distance and spectrum correlation optimization alignment for two-dimensional gas chromatography time-of-flight mass spectrometry-based metabolomics.Anal Chem. 2010 Jun 15;82(12):5069-81. doi: 10.1021/ac100064b. Anal Chem. 2010. PMID: 20476746 Free PMC article.
LinkOut - more resources
Full Text Sources