Analytical interferences and analytical quality
- PMID: 19306857
- DOI: 10.1016/j.cca.2009.03.031
Analytical interferences and analytical quality
Abstract
In today's health care system the prevalence of medical errors is high as stated by the report of the Institute of Medicine. A varying error rate of <10% in clinical medical laboratories has been reported in the literature. Most of these errors occur in the pre-analytical phase. Only a small number of errors will be seen in the analytical phase. This overview will deal with the analytical interferences and will offer ways to improve the analytical quality. Some special areas of the analytical process like calibration, quality control, reference interval, drug interference, statistical analysis and volume displacement will be covered. With some examples from the literature and own investigations the impact of errors in these steps of the analytical process will be better understood and the examples will help reducing the number of analytical errors and interferences. This finally provides better patient safety.
Similar articles
-
Medical errors: impact on clinical laboratories and other critical areas.Clin Biochem. 2004 Dec;37(12):1052-62. doi: 10.1016/j.clinbiochem.2004.08.009. Clin Biochem. 2004. PMID: 15589810 Review.
-
Laboratory safety and the WHO World Alliance for Patient Safety.Clin Chim Acta. 2009 Jun;404(1):6-11. doi: 10.1016/j.cca.2009.03.019. Epub 2009 Mar 18. Clin Chim Acta. 2009. PMID: 19302992
-
Pre-analytical workstations: a tool for reducing laboratory errors.Clin Chim Acta. 2009 Jun;404(1):68-74. doi: 10.1016/j.cca.2009.03.024. Epub 2009 Mar 18. Clin Chim Acta. 2009. PMID: 19302988
-
Exploring the iceberg of errors in laboratory medicine.Clin Chim Acta. 2009 Jun;404(1):16-23. doi: 10.1016/j.cca.2009.03.022. Epub 2009 Mar 18. Clin Chim Acta. 2009. PMID: 19302995
-
Errors in pathology and laboratory medicine: consequences and prevention.J Surg Oncol. 2004 Dec 1;88(3):161-81. doi: 10.1002/jso.20125. J Surg Oncol. 2004. PMID: 15562462 Review.
Cited by
-
Analytical Interference in Chemiluminescence Assay-Measured Angiotensin I, Angiotensin II, Aldosterone, and Renin.J Clin Lab Anal. 2024 May;38(10):e25045. doi: 10.1002/jcla.25045. Epub 2024 Jun 1. J Clin Lab Anal. 2024. PMID: 38822626 Free PMC article.
-
Evaluating laboratory request forms submitted to haematology and blood transfusion departments at a hospital in Northwest Nigeria.Afr J Lab Med. 2016 May 12;5(1):381. doi: 10.4102/ajlm.v5i1.381. eCollection 2016. Afr J Lab Med. 2016. PMID: 28879111 Free PMC article.
-
A guide for measurement of circulating metabolic hormones in rodents: Pitfalls during the pre-analytical phase.Mol Metab. 2012 Aug 9;1(1-2):47-60. doi: 10.1016/j.molmet.2012.07.004. eCollection 2012. Mol Metab. 2012. PMID: 24024118 Free PMC article.
-
Les médicaments qui interfèrent avec les bilans biologiques : revue de la littérature.Can J Hosp Pharm. 2021 Fall;74(4):378-385. doi: 10.4212/c-jhp.v74i4.3200. Can J Hosp Pharm. 2021. PMID: 34602626 Free PMC article. French.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical