Abstract
Objective: The purpose of this study was to evaluate the accuracy of clinical measurement of cervical dilation with a position-tracking system during vaginal examination.
Study design: This prospective study that was conducted in Poissy, France, Brooklyn, NY, and Haifa, Israel, included 333 measurements that were performed in 188 women with term singleton vertex uncomplicated pregnancies during the active stage of labor. Ninety measurements with clinical diagnosis of full dilation were excluded from analysis. Measurements were performed with a sensor attached to the midwife's index fingertip and a position-tracking system that was based on a low magnetic field. Evaluations were done when cervical examinations were clinically indicated.
Results: Results were similar in all centers. Mean error was 10.2 +/- 8.4 mm and ranged from 7.5 +/- 7.3 mm, when cervical dilation was > 8 cm, to 12.5 +/- 8.7 mm when cervical dilation was between 6.1 and 8 cm.
Conclusion: This first evaluation of cervical assessment accuracy during vaginal examination with a position-tracking system shows limited precision.
Similar articles
-
Determination of fetal head station and position during labor: a new technique that combines ultrasound and a position-tracking system.Am J Obstet Gynecol. 2009 Apr;200(4):404.e1-5. doi: 10.1016/j.ajog.2008.10.051. Epub 2009 Feb 14. Am J Obstet Gynecol. 2009. PMID: 19217593
-
Accuracy of simulated cervical dilation and effacement measurements among practitioners.Am J Obstet Gynecol. 2004 Nov;191(5):1797-9. doi: 10.1016/j.ajog.2004.07.062. Am J Obstet Gynecol. 2004. PMID: 15547567
-
Comparison of the learning curves of digital examination and transabdominal sonography for the determination of fetal head position during labor.Ultrasound Obstet Gynecol. 2008 Mar;31(3):332-7. doi: 10.1002/uog.5267. Ultrasound Obstet Gynecol. 2008. PMID: 18307213
-
Cervical dilation: accuracy of visual and digital examinations.Obstet Gynecol. 1993 Feb;81(2):215-6. Obstet Gynecol. 1993. PMID: 8423953
-
Accuracy of cervical assessment in the active phase of labour.BJOG. 2007 Jul;114(7):833-7. doi: 10.1111/j.1471-0528.2007.01386.x. BJOG. 2007. PMID: 17567418
Cited by
-
Agreement between transperineal ultrasound measurements and digital examinations of cervical dilatation during labor.BMC Pregnancy Childbirth. 2015 Oct 24;15:273. doi: 10.1186/s12884-015-0704-z. BMC Pregnancy Childbirth. 2015. PMID: 26496894 Free PMC article.
-
Ultrasound-based fetal tracking technology during labor: is it the next best thing?J Perinat Educ. 2012 Winter;21(1):52-4. doi: 10.1891/1058-1243.21.1.52. J Perinat Educ. 2012. PMID: 23277732 Free PMC article.
-
New techniques in evaluation of the cervix.Semin Perinatol. 2017 Dec;41(8):477-484. doi: 10.1053/j.semperi.2017.08.006. Semin Perinatol. 2017. PMID: 29191290 Free PMC article. Review.
-
Cervical Evaluation: From Ancient Medicine to Precision Medicine.Obstet Gynecol. 2017 Jul;130(1):51-63. doi: 10.1097/AOG.0000000000002106. Obstet Gynecol. 2017. PMID: 28594774 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources