Development of an automated chemiluminescence flow-through sensor for the determination of 5-aminosalicylic acid in pharmaceuticals: a comparative study between sequential and multicommutated flow techniques
- PMID: 19326104
- DOI: 10.1007/s00216-009-2757-1
Development of an automated chemiluminescence flow-through sensor for the determination of 5-aminosalicylic acid in pharmaceuticals: a comparative study between sequential and multicommutated flow techniques
Abstract
This work is aimed at demonstrating the potential of the implementation of automatic flow systems in optosensors using chemiluminescence detection. With this purpose, two automatic methodologies, multicommutation and sequential injection analysis (SIA), have been applied to the analysis of 5-aminosalicylic acid (ASA). The analyte is determined for the first time making use of its chemiluminescence reaction with permanganate anion, previously immobilized on an appropriate solid support in the detection area. First, the study of the most appropriate commercial flow-through cell and the optimum conditions for the reaction were performed. Second, the main differences in terms of flow variables and analytical parameters for multicommutation and SIA approaches were stated. Both methodologies were applied to the determination of the analyte in pharmaceuticals obtaining satisfactory results. Finally, the advantages and disadvantages of both proposed methods and the recoveries obtained from pharmaceuticals were statistically compared.
Similar articles
-
Development of a multicommuted flow-through optosensor for the determination of a ternary pharmaceutical mixture.J Pharm Biomed Anal. 2007 Jan 17;43(2):515-21. doi: 10.1016/j.jpba.2006.08.003. Epub 2006 Sep 15. J Pharm Biomed Anal. 2007. PMID: 16978822
-
Fast determination of salicylic acid in pharmaceuticals by using a terbium-sensitized luminescent SIA optosensor.J Pharm Sci. 2008 Feb;97(2):791-7. doi: 10.1002/jps.21013. J Pharm Sci. 2008. PMID: 17876766
-
Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals.J Pharm Biomed Anal. 2007 Nov 5;45(3):367-81. doi: 10.1016/j.jpba.2007.08.018. Epub 2007 Aug 21. J Pharm Biomed Anal. 2007. PMID: 17900844 Review.
-
Fluorimetric SIA optosensing in pharmaceutical analysis: determination of paracetamol.J Pharm Biomed Anal. 2007 Oct 18;45(2):318-21. doi: 10.1016/j.jpba.2007.05.004. Epub 2007 May 10. J Pharm Biomed Anal. 2007. PMID: 17587530
-
Recent progress of flow-through optosensing in clinical and pharmaceutical analysis.J Pharm Biomed Anal. 2010 Nov 2;53(3):250-61. doi: 10.1016/j.jpba.2010.04.020. Epub 2010 Apr 20. J Pharm Biomed Anal. 2010. PMID: 20452162 Review.