[Contralateral occlusion of the internal carotid artery in the study of carotid stenosis using Doppler ultrasonography]
- PMID: 19340780
[Contralateral occlusion of the internal carotid artery in the study of carotid stenosis using Doppler ultrasonography]
Abstract
Introduction and aims: The degree of stenosis measured by Doppler ultrasonography in patients with contralateral occlusion of the internal carotid artery (ICA) is assumed to be overestimated. We propose to measure the extent to which this phenomenon affects the capacity of Doppler ultrasonography to classify stenoses.
Patients and methods: A retrospective study of 47 patients was conducted using Doppler ultrasonography and digital subtraction angiography; all subjects had confirmed unilateral occlusion of the ICA and stenoses of the contralateral ICA. Curves were traced plotting the degree of stenosis against the peak systolic velocity (PSV) and its ratio in the ICA and in the common carotid artery (VICA/VCCA). The curves were compared with their equivalents with no contralateral occlusion found in the literature. Later, the cases of stenosis were classified into groups of less than 50, 50-69 and more than 70%, and the main statistical values were calculated.
Results: The PSV in the stenoses between 40-50% presents more than 1 standard deviation (SD) above the mean. There were no significant deviations in other degrees of stenosis (p > 0.4). The VICA/VCCA showed a similar parallelism, but with deviations lower than 1 SD (p = 0.56). Seventeen per cent of the stenoses were over-classified, and this conditioned a sensitivity of 84, 71 and 100%, and a specificity of 100, 94 and 88% for the groups of less than 50, 50-69 and over 70%, respectively. The VICA/VCCA over-classified 41% of the stenoses; sensitivity was seen to be 56, 43 and 100% and specificity was 90, 64 and 87%. Diagnostic accuracy of the PSV and VICA/VCCA stands at 83 and 57%, respectively.
Conclusions: Contralateral occlusion leads to over-classification of the PSV. There is a tendency to over-classify, although this does not affect the overall diagnostic accuracy. The VICA/VCCA does not offer greater diagnostic accuracy in classifying stenoses with contralateral occlusion.
Similar articles
-
Ability to use duplex US to quantify internal carotid arterial stenoses: fact or fiction?Radiology. 2000 Jan;214(1):247-52. doi: 10.1148/radiology.214.1.r00ja27247. Radiology. 2000. PMID: 10644132
-
[Center specific duplex Doppler threshold values in carotid artery stenosis].Tani Girisim Radyol. 2004 Jun;10(2):167-72. Tani Girisim Radyol. 2004. PMID: 15236136 Turkish.
-
Duplex ultrasound velocity criteria for the stented carotid artery.J Vasc Surg. 2008 Jan;47(1):63-73. doi: 10.1016/j.jvs.2007.09.038. J Vasc Surg. 2008. PMID: 18178455
-
Carotid artery stenosis: gray-scale and Doppler US diagnosis--Society of Radiologists in Ultrasound Consensus Conference.Radiology. 2003 Nov;229(2):340-6. doi: 10.1148/radiol.2292030516. Epub 2003 Sep 18. Radiology. 2003. PMID: 14500855 Review.
-
Carotid artery stenosis: grayscale and Doppler ultrasound diagnosis--Society of Radiologists in Ultrasound consensus conference.Ultrasound Q. 2003 Dec;19(4):190-8. doi: 10.1097/00013644-200312000-00005. Ultrasound Q. 2003. PMID: 14730262 Review.
Cited by
-
Ultrasonographical Features Associated with Progression of Atherosclerosis in Patients with Moderate Internal Carotid Artery Stenosis.Transl Stroke Res. 2018 Aug;9(4):375-381. doi: 10.1007/s12975-017-0592-9. Epub 2017 Dec 1. Transl Stroke Res. 2018. PMID: 29196884
MeSH terms
LinkOut - more resources
Miscellaneous