Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure
- PMID: 19345360
- DOI: 10.1016/j.jbiomech.2009.02.011
Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure
Abstract
Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, finger and ear photoplethysmogram were recorded from 15 subjects with the right arm at five different positions (90 degrees , 45 degrees , 0 degrees , -45 degrees and -90 degrees referred to the horizontal level). Arm pulse propagation time was determined by subtracting ear pulse transit time from finger pulse transit time, and was used to obtain arterial volume distensibility. The mean arterial blood pressure with the arm at the horizontal level was acquired, and changes with position were calculated using the hydrostatic principle that blood pressure in the arm is linearly related to its vertical distance from the horizontal level. The mean arm pulse propagation times for the five different positions were 88, 72, 57, 54 and 52ms, with the corresponding mean arterial volume distensibility of 0.234%, 0.158%, 0.099%, 0.088% and 0.083% per mmHg. For all consecutive changes in arm position, arm pulse propagation time and arterial volume distensibility, were significantly different (all probability P<0.05). The slopes of arm pulse propagation time and arterial volume distensibility against arterial pressure decreased significantly between each consecutive arm position from 90 degrees to -45 degrees (all P<0.01), indicating significant non-linearity. The experimental results fitted the physiological exponential model and Langewouters' arctangent model well, and were also comparable to published data with arterial volume distensibility approximately tripling for transmural pressure changes from 101 to 58mmHg. In conclusion, the inverse and non-linear relationship between arterial volume distensibility and arterial pressure has been quantified using a simple arm positioning procedure, with the greatest effect at low pressures. This work is an important step in developing a simple non-invasive technique for assessing peripheral arterial volume distensibility.
Similar articles
-
Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure.Physiol Meas. 2011 May;32(5):499-512. doi: 10.1088/0967-3334/32/5/001. Epub 2011 Mar 21. Physiol Meas. 2011. PMID: 21422513
-
Non-invasive in vivo assessment of changes in peripheral arterial properties with estimation of arterial volume compliance.Physiol Meas. 2007 Oct;28(10):1317-27. doi: 10.1088/0967-3334/28/10/015. Epub 2007 Sep 28. Physiol Meas. 2007. PMID: 17906397
-
Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance.Clin Physiol Funct Imaging. 2007 Nov;27(6):354-62. doi: 10.1111/j.1475-097X.2007.00759.x. Clin Physiol Funct Imaging. 2007. PMID: 17944657
-
Noninvasive assessment of arterial pressure.Curr Opin Crit Care. 2008 Jun;14(3):317-21. doi: 10.1097/MCC.0b013e3282fd6e31. Curr Opin Crit Care. 2008. PMID: 18467893 Review.
-
Pulse transit time as an indirect marker for variations in cardiovascular related reactivity.Technol Health Care. 2006;14(2):97-108. Technol Health Care. 2006. PMID: 16720953 Review.
Cited by
-
Changes in the bilateral pulse transit time difference with a moving arm.Technol Health Care. 2018;26(S1):113-119. doi: 10.3233/THC-174256. Technol Health Care. 2018. PMID: 29710744 Free PMC article.
-
Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method.Eur J Appl Physiol. 2012 Jan;112(1):309-15. doi: 10.1007/s00421-011-1983-3. Epub 2011 May 10. Eur J Appl Physiol. 2012. PMID: 21556814
-
Assessing the acute effect of compression socks on improving arterial compliance in young volunteers.Heliyon. 2025 Jan 10;11(2):e41704. doi: 10.1016/j.heliyon.2025.e41704. eCollection 2025 Jan 30. Heliyon. 2025. PMID: 39897788 Free PMC article.
-
Peripheral arterial volume distensibility changes with applied external pressure: significant difference between arteries with different compliance.Sci Rep. 2017 Jan 17;7:40545. doi: 10.1038/srep40545. Sci Rep. 2017. PMID: 28094277 Free PMC article.
-
A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China.Sci Data. 2018 Feb 27;5:180020. doi: 10.1038/sdata.2018.20. Sci Data. 2018. PMID: 29485624 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources