Assessing the effect of a contouring protocol on postprostatectomy radiotherapy clinical target volumes and interphysician variation
- PMID: 19345515
- DOI: 10.1016/j.ijrobp.2008.12.042
Assessing the effect of a contouring protocol on postprostatectomy radiotherapy clinical target volumes and interphysician variation
Abstract
Purpose: To compare postprostatectomy clinical target volume (CTV) delineation before and after the introduction of a contouring protocol and to investigate its effect on interphysician variability
Methods and materials: Six site-specialized radiation oncologists independently delineated a CTV on the computed tomography (CT) scans of 3 patients who had received postprostatectomy radiotherapy. At least 3 weeks later this was repeated, but with the physicians adhering to the contouring protocol from the Medical Research Council's Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trial. The volumes obtained before and after the protocol were compared and the effect of the protocol on interphysician variability assessed.
Results: An increase in mean CTV for all patients of 40.7 to 53.9 cm(3) was noted as a result of observing the protocol, with individual increases in the mean CTV of 65%, 15%, and 24% for Patients 1, 2, and 3 respectively. A reduction in interphysician variability was noted when the protocol was used.
Conclusions: Substantial interphysician variation in target volume delineation for postprostatectomy radiotherapy exists, which can be reduced by the use of a contouring protocol. The RADICALS contouring protocol increases the target volumes when compared with those volumes typically applied at our center. The effect of treating larger volumes on the therapeutic ratio and resultant toxicity should be carefully monitored, particularly if the same dose-response as documented in radical prostate radiotherapy applies to the adjuvant and salvage setting. Prostate cancer, Postprostatectomy, Radiotherapy, Target volume.
Similar articles
-
[Changes in target volumes definition by using MRI for prostate bed radiotherapy planning--preliminary results].Klin Onkol. 2010;23(4):256-63. Klin Onkol. 2010. PMID: 20806824 Czech.
-
Anatomic variations due to radical prostatectomy. Impact on target volume definition and dose-volume parameters of rectum and bladder.Strahlenther Onkol. 2004 Sep;180(9):563-72. doi: 10.1007/s00066-004-1245-y. Strahlenther Onkol. 2004. PMID: 15378187 Clinical Trial.
-
Magnetic resonance imaging in postprostatectomy radiotherapy planning.Int J Radiat Oncol Biol Phys. 2012 Feb 1;82(2):911-8. doi: 10.1016/j.ijrobp.2010.11.004. Epub 2011 Mar 21. Int J Radiat Oncol Biol Phys. 2012. PMID: 21420244
-
Development of RTOG consensus guidelines for the definition of the clinical target volume for postoperative conformal radiation therapy for prostate cancer.Int J Radiat Oncol Biol Phys. 2010 Feb 1;76(2):361-8. doi: 10.1016/j.ijrobp.2009.02.006. Epub 2009 Apr 23. Int J Radiat Oncol Biol Phys. 2010. PMID: 19394158 Free PMC article.
-
[Target volume for adjuvant radiotherapy after prostatectomy].Cancer Radiother. 2007 Nov;11(6-7):358-62. doi: 10.1016/j.canrad.2007.08.004. Epub 2007 Sep 20. Cancer Radiother. 2007. PMID: 17888706 Review. French.
Cited by
-
MRI-based radiomics in breast cancer: feature robustness with respect to inter-observer segmentation variability.Sci Rep. 2020 Aug 25;10(1):14163. doi: 10.1038/s41598-020-70940-z. Sci Rep. 2020. PMID: 32843663 Free PMC article.
-
Maintaining prostate contouring consistency following an educational intervention.J Med Radiat Sci. 2016 Sep;63(3):155-60. doi: 10.1002/jmrs.168. Epub 2016 Mar 16. J Med Radiat Sci. 2016. PMID: 27648279 Free PMC article.
-
Experience and uncertainty analysis of CT-based adaptive radiotherapy for abdominal treatments.Phys Med. 2025 Mar;131:104946. doi: 10.1016/j.ejmp.2025.104946. Epub 2025 Feb 27. Phys Med. 2025. PMID: 40020400
-