Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 May 1;45(4):1289-304.
doi: 10.1016/j.neuroimage.2009.01.017. Epub 2009 Jan 24.

Simultaneous MEG and intracranial EEG recordings during attentive reading

Affiliations
Free article

Simultaneous MEG and intracranial EEG recordings during attentive reading

Sarang S Dalal et al. Neuroimage. .
Free article

Abstract

The relationship between neural oscillations recorded at various spatial scales remains poorly understood partly due to an overall dearth of studies utilizing simultaneous measurements. In an effort to study quantitative markers of attention during reading, we performed simultaneous magnetoencephalography (MEG) and intracranial electroencephalography (iEEG) recordings in four epileptic patients. Patients were asked to attend to a specific color when presented with an intermixed series of red words and green words, with words of a given color forming a cohesive story. We analyzed alpha, beta, and gamma band oscillatory responses to the word presentation and compared the strength and spatial organization of those responses in both electrophysiological recordings. Time-frequency analysis of iEEG revealed a network of clear attention-modulated high gamma band (50-150 Hz) power increases and alpha/beta (9-25 Hz) suppressions in response to the words. In addition to analyses at the sensor level, MEG time-frequency analysis was performed at the source level using a sliding window beamformer technique. Strong alpha/beta suppressions were observed in MEG reconstructions, in tandem with iEEG effects. While the MEG counterpart of high gamma band enhancement was difficult to interpret at the sensor level in two patients, MEG time-frequency source reconstruction revealed additional activation patterns in accordance with iEEG results. Importantly, iEEG allowed us to confirm that several sources of gamma band modulation observed with MEG were indeed of cortical origin rather than EMG muscular or ocular artifact.

PubMed Disclaimer

Publication types