Raman spectroscopy of bladder tissue in the presence of 5-aminolevulinic acid
- PMID: 19362851
- DOI: 10.1016/j.jphotobiol.2009.03.002
Raman spectroscopy of bladder tissue in the presence of 5-aminolevulinic acid
Abstract
Raman spectroscopy has the ability to provide differential diagnosis of different cancers with high sensitivity and specificity. A major limitation in its clinical application is the weak nature of Raman signal, which inhibits scanning large surface areas of tissues. In bladder cancer diagnosis, fluorescence-guided endoscopy with 5-aminolevulinic acid (5-ALA) has gained interest as a technique that can provide such spatial differentiation, thus improving early detection and more complete removal of superficial tumors. However, several studies have demonstrated the poor specificity of this modality. Combining fluorescence with Raman spectroscopy could improve its diagnostic capability. However, little is known about the effect of agents such as 5-ALA on Raman spectra of tissue. In this paper, we present measuring Raman spectroscopy from benign and malignant bladder tissues in the presence of 5-ALA and attempt to evaluate the potential to discriminate between different pathologies. Raman spectra were recorded from 92 bladder biopsies without 5-ALA and 38 biopsies with 5-ALA using a Raman microspectrometer system at 830nm excitation. Empirical and multivariate statistical techniques were used for data analysis. Algorithms were developed to determine the effect of 5-ALA on tissue and its influence on the prediction ability of a preliminary benign/malignant prediction model. In samples with 5-ALA, an overall decrease in Raman intensity was observed when compared to the Raman spectra from samples without 5-ALA. Additionally, differences in relative intensities at 1270 and 1330cm(-1) were also noted. However, significant differences were observed in the Raman spectra of benign and malignant samples with 5-ALA indicating the potential of using Raman spectroscopy for discriminating bladder cancer in the presence of 5-ALA. The Principal-Component fed Linear-Discriminant Analysis (PCA/LDA) algorithm derived from biopsies in the absence of 5-ALA used to predict biopsies in the presence of 5-ALA resulted in an overall sensitivity and specificity of 42.6% and 71.1%, respectively. This suggests the presence of 5-ALA in tissue affects the Raman spectra. A PCA/LDA algorithm based on fluorescence information (i.e. PpIX fluorescence positive or negative) and the Raman spectrum of 5-ALA biopsies, had a sensitivity and specificity of 100% and 80.8%, respectively. This study demonstrates that applying 5-ALA affects the Raman spectra of bladder tissues. However, benign/malignant differentiation can be accomplished with a preliminary PCA/LDA algorithm, suggesting the potential of a combined diagnostic modality in vivo.
Similar articles
-
Signal-to-noise contribution of principal component loads in reconstructed near-infrared Raman tissue spectra.Appl Spectrosc. 2010 Jan;64(1):8-14. doi: 10.1366/000370210790572052. Appl Spectrosc. 2010. PMID: 20132590
-
Diagnostic potential of near-infrared Raman spectroscopy in the stomach: differentiating dysplasia from normal tissue.Br J Cancer. 2008 Jan 29;98(2):457-65. doi: 10.1038/sj.bjc.6604176. Epub 2008 Jan 15. Br J Cancer. 2008. PMID: 18195711 Free PMC article.
-
Raman spectroscopy to differentiate between fresh tissue samples of glioma and normal brain: a comparison with 5-ALA-induced fluorescence-guided surgery.J Neurosurg. 2020 Oct 2;135(2):469-479. doi: 10.3171/2020.5.JNS20376. Print 2021 Aug 1. J Neurosurg. 2020. PMID: 33007757
-
Hexyl aminolevulinate: 5-ALA hexylester, 5-ALA hexylesther, aminolevulinic acid hexyl ester, hexaminolevulinate, hexyl 5-aminolevulinate, P 1206.Drugs R D. 2005;6(4):235-8. doi: 10.2165/00126839-200506040-00007. Drugs R D. 2005. PMID: 15991884 Review.
-
Raman spectroscopy for medical diagnostics--From in-vitro biofluid assays to in-vivo cancer detection.Adv Drug Deliv Rev. 2015 Jul 15;89:121-34. doi: 10.1016/j.addr.2015.03.009. Epub 2015 Mar 22. Adv Drug Deliv Rev. 2015. PMID: 25809988 Review.
Cited by
-
Image-guided Raman spectroscopy probe-tracking for tumor margin delineation.J Biomed Opt. 2021 Mar;26(3):036002. doi: 10.1117/1.JBO.26.3.036002. J Biomed Opt. 2021. PMID: 33715315 Free PMC article.
-
Raman Spectroscopy for Instant Bladder Tumor Diagnosis: System Development and In Vivo Proof-Of-Principle Study in Accordance with the European Medical Device Regulation (MDR2017/745).Cancers (Basel). 2024 Sep 23;16(18):3238. doi: 10.3390/cancers16183238. Cancers (Basel). 2024. PMID: 39335209 Free PMC article.
-
The tumour is not enough or is it? Problems and new concepts in the surgery of cerebral metastases.Ecancermedicalscience. 2013 Apr 18;7:306. doi: 10.3332/ecancer.2013.306. Print 2013. Ecancermedicalscience. 2013. PMID: 23653671 Free PMC article.
-
The complementary value of intraoperative fluorescence imaging and Raman spectroscopy for cancer surgery: combining the incompatibles.Eur J Nucl Med Mol Imaging. 2022 Jun;49(7):2364-2376. doi: 10.1007/s00259-022-05705-z. Epub 2022 Feb 1. Eur J Nucl Med Mol Imaging. 2022. PMID: 35102436 Free PMC article. Review.
-
Experience Profiling of Fluorescence-Guided Surgery II: Non-Glioma Pathologies.Brain Tumor Res Treat. 2019 Oct;7(2):105-111. doi: 10.14791/btrt.2019.7.e39. Brain Tumor Res Treat. 2019. PMID: 31686441 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical