Carotid computed tomography angiography with automated bone suppression: a comparative study between dual energy and bone subtraction techniques
- PMID: 19363448
- DOI: 10.1097/RLI.0b013e31819e8ad9
Carotid computed tomography angiography with automated bone suppression: a comparative study between dual energy and bone subtraction techniques
Abstract
Objectives: Computed tomography angiography (CTA) is a well-accepted imaging modality to evaluate the vessels of the head and neck. To improve the assessment of vessels at or within the skull base, different techniques to suppress bone in the final CTA image have been developed. We sought to compare the performance of fully automated bone removal based on dual energy (DE) and image registration (bone subtraction CTA [BSCTA]) for the supraaortic vasculature.
Materials and methods: Twenty-seven patients underwent carotid CTA on a dual source CT system. Two scans were performed, one before and one after contrast agent injection in DE mode (simultaneous acquisition of 80 and 140 kV scans). For each patient, data sets were reconstructed for post processing with DE and BSCTA. Two examiners evaluated overall bone suppression and image quality regarding integrity of the vessel lumen of different vessel segments (n = 19) with a 5-point scale (1 = poor, 5 = excellent), CTA source data served as the reference. Wilcoxon signed rank test was used to determine differences between the techniques. Cohen's kappa was used to determine interobserver agreement.
Results: Both bone suppression techniques could be applied successfully in 25 patients with high overall image quality. Two patients were excluded from the evaluation for technical reasons. Interobserver agreement was excellent (kappa = 0.85). Mean score of all vessel segments for overall bone removal was 4.45 +/- 0.76 for DE and 4.33 +/- 1.02 for BSCTA; DE performed better in the vessel segment of the neck (external carotid artery, common carotid artery, V1 to V3 segment of the vertebral artery, subclavian artery), whereas BSCTA was superior in the cranial vessels (C3-C6 segment of the internal carotid artery, ophthalmic artery). Vessel integrity was superior with BSCTA, the mean score of all vessel segments for overall vessel integrity was 3.97 +/- 1.47 for DE and 4.49 +/- 0.98 for BSCTA, the subclavian artery was most frequently truncated using DE post processing (mean score: 1.44 +/- 1.2).
Conclusions: Both techniques provided bone suppression in a fully automated way. DE provided more complete bone suppression in the neck, but at the cost of inferior vessel integrity, especially at the thoracic inlet. BSCTA showed excellent results for vessel integrity and was superior to DE in most of the vessels in or at the skull base.
Similar articles
-
Dual energy CTA of the supraaortic arteries: technical improvements with a novel dual source CT system.Eur J Radiol. 2010 Nov;76(2):e6-12. doi: 10.1016/j.ejrad.2009.09.022. Epub 2009 Oct 9. Eur J Radiol. 2010. PMID: 19819092
-
Cranial computed tomography angiography with automated bone subtraction: a feasibility study.Invest Radiol. 2009 Jan;44(1):38-43. doi: 10.1097/RLI.0b013e31818c3d6b. Invest Radiol. 2009. PMID: 18836384
-
Cervical CT angiography comparing routine noncontrast and a late venous scan as masks for automated bone subtraction: feasibility study and examination of the influence of patient motion on image quality.Invest Radiol. 2008 Jan;43(1):27-32. doi: 10.1097/RLI.0b013e31815597ac. Invest Radiol. 2008. PMID: 18097274
-
Carotid vessel evaluation via a 3-D workstation.Radiol Technol. 2013 Sep-Oct;85(1):107-11. Radiol Technol. 2013. PMID: 24029893 Review. No abstract available.
-
Dual-source computed tomography for the evaluation of nephrolithiasis.J Am Coll Radiol. 2009 Sep;6(9):656-8. doi: 10.1016/j.jacr.2009.05.002. J Am Coll Radiol. 2009. PMID: 19720363 Review. No abstract available.
Cited by
-
Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT.Radiology. 2010 Jul;256(1):184-90. doi: 10.1148/radiol.10091411. Radiology. 2010. PMID: 20574095 Free PMC article.
-
128-slice acceletated-pitch dual energy CT angiography of the head and neck: comparison of different low contrast medium volumes.PLoS One. 2013 Nov 19;8(11):e80939. doi: 10.1371/journal.pone.0080939. eCollection 2013. PLoS One. 2013. PMID: 24260516 Free PMC article. Clinical Trial.
-
Clinical applications of dual-energy CT in head and neck imaging.Eur Arch Otorhinolaryngol. 2016 Mar;273(3):547-53. doi: 10.1007/s00405-014-3417-4. Epub 2014 Dec 4. Eur Arch Otorhinolaryngol. 2016. PMID: 25472819 Review.
-
Advances in CT Techniques in Vascular Calcification.Front Cardiovasc Med. 2021 Sep 29;8:716822. doi: 10.3389/fcvm.2021.716822. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 34660718 Free PMC article. Review.
-
A Comparative Study of AI-Based Automated and Manual Postprocessing of Head and Neck CT Angiography: An Independent External Validation with Multi-Vendor and Multi-Center Data.Neuroradiology. 2024 Oct;66(10):1765-1780. doi: 10.1007/s00234-024-03379-y. Epub 2024 May 16. Neuroradiology. 2024. PMID: 38753039
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous