Neurovascular imaging at 1.5 tesla versus 3.0 tesla
- PMID: 19364598
- DOI: 10.1016/j.mric.2008.12.005
Neurovascular imaging at 1.5 tesla versus 3.0 tesla
Abstract
The primary advantage of high field strength MR imaging over imaging on modern 1.5 Tesla (T) systems is increased signal-to-noise ratio, which can be used to improve image quality or shorten scan acquisition time. In the years since 3.0T scanners were first approved for clinical use, one of the areas which has benefited greatly from its introduction is neurovascular MR angiography (MRA). Early experience has shown significant improvements in resolution and image quality. Whether high field strength MRA is robust or accurate enough to replace digital subtraction angiography in the foreseeable future remains to be seen. This article discusses the current state of neurovascular MRA at 3.0T, basic physical differences between MR imaging at 1.5T and 3.0T, and their effects on MRA sequences. The literature regarding the efficacy of 3.0T MRA techniques for diagnosing specific neurovascular pathologies and carotid steno occlusive disease is reviewed.
Similar articles
-
Assessment of 3D-TOF-MRA at 3.0 Tesla in the characterization of the angioarchitecture of cerebral arteriovenous malformations: a preliminary study.Acta Radiol. 2007 Jul;48(6):678-86. doi: 10.1080/02841850701326958. Acta Radiol. 2007. PMID: 17611878 Clinical Trial.
-
Neuroradiologic applications of dynamic MR angiography at 3 T.Magn Reson Imaging Clin N Am. 2009 Feb;17(1):63-75. doi: 10.1016/j.mric.2009.01.004. Magn Reson Imaging Clin N Am. 2009. PMID: 19364600
-
Evaluation of intracranial aneurysms with 7 T versus 1.5 T time-of-flight MR angiography - initial experience.Rofo. 2009 Jan;181(1):16-23. doi: 10.1055/s-2008-1027863. Epub 2008 Dec 29. Rofo. 2009. PMID: 19115164
-
Extracranial carotid MR imaging at 3T.Magn Reson Imaging Clin N Am. 2006 Feb;14(1):109-21. doi: 10.1016/j.mric.2005.12.003. Magn Reson Imaging Clin N Am. 2006. PMID: 16530639 Review.
-
Pulmonary MR angiography techniques and applications.Magn Reson Imaging Clin N Am. 2009 Feb;17(1):101-31. doi: 10.1016/j.mric.2009.01.001. Magn Reson Imaging Clin N Am. 2009. PMID: 19364603 Review.
Cited by
-
Amygdala structure and aggressiveness in borderline personality disorder.Eur Arch Psychiatry Clin Neurosci. 2018 Jun;268(4):417-427. doi: 10.1007/s00406-016-0747-9. Epub 2016 Nov 22. Eur Arch Psychiatry Clin Neurosci. 2018. PMID: 27878376
-
Accuracy of 3 T MR angioraphy in vertebral artery stenosis and coincidence with other cerebrovascular stenoses.Neuroradiology. 2010 Oct;52(10):893-8. doi: 10.1007/s00234-010-0655-z. Epub 2010 Jan 28. Neuroradiology. 2010. PMID: 20107775
-
One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results.Br J Radiol. 2021 Dec;94(1128):20210589. doi: 10.1259/bjr.20210589. Epub 2021 Oct 5. Br J Radiol. 2021. PMID: 34558306 Free PMC article.
-
Comparative analysis of fluorescent angiography, computed tomographic angiography and magnetic resonance angiography for planning autologous breast reconstruction.Gland Surg. 2015 Apr;4(2):164-78. doi: 10.3978/j.issn.2227-684X.2015.03.06. Gland Surg. 2015. PMID: 26005648 Free PMC article.
-
Carotid plaque regression following 6-month statin therapy assessed by 3T cardiovascular magnetic resonance: comparison with ultrasound intima media thickness.J Cardiovasc Magn Reson. 2011 Aug 3;13(1):37. doi: 10.1186/1532-429X-13-37. J Cardiovasc Magn Reson. 2011. PMID: 21812992 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources