Abstract
Purpose: To evaluate and compare posterior capsule opacification (PCO) incidence and the best-corrected visual acuity (BCVA) in patients who underwent the implantation of intraocular lens (IOL) made of polymethylmethacrylate (PMMA), or hydrophobic acrylic material, or silicone material. All patients were examined 7 years after the surgery at the Department of Ophthalmology, University Hospital, Hradec Králové, Czech Republic, E.U.
Methods: In this 60 study, sixty eyes (44 patients) were evaluated; 20 eyes with IOLs made of PMMA with round edge, 20 eyes with IOLs made of hydrophobic acrylic material with square edge and 20 eyes with IOLs made of silicone material with round edge. They were examined 7 years after surgery. The eyes treated with Nd:YAG laser capsulotomy were excluded from the EPCO 2000 evaluation. The EPCO 2000 software (Evaluation of Posterior Capsule Opacification) was used for PCO assessment. The density of the opacification was graded clinically from 1 to 4. The BCVA, the PCO index for every PCO grade and total PCO index were compared.
Results: Mean of total PCO index for PMMA IOLs was 0.451 +/- 0.619; for hydrophobic acrylic IOLs 0.361 +/- 0.397; and for silicone IOLs 0.552 +/- 0.372. During the examination, we have found the BCVA mean to be for PMMA IOLs 0.79 +/- 0.26, for hydrophobic acrylic IOLs 0.87 +/- 0.19, and silicone IOLs 0.78 +/- 0.29 respectively. Twenty eyes of twenty patients required Nd:YAG laser capsulotomy: twelve eyes with PMMA IOLs, two eyes with hydrophobic acrylic IOLs, and six eyes with silicone IOLs.
Conclusions: In this study, the difference in PCO incidence and BCVA among PMMA, hydrophobic acrylic, and silicone IOLs were not statistically significant. The highest incidence of the Nd:YAG laser capsulotomy was in the group of PMMA IOLs, then in silicone IOLs, and the lowest incidence was in the group of hydrophobic acrylic IOLs.
Similar articles
-
[Comparison of posterior capsule opacification in 2 types of implanted artificial intraocular lens].Cesk Slov Oftalmol. 2007 Jan;63(1):42-6. Cesk Slov Oftalmol. 2007. PMID: 17361627 Czech.
-
Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification.Ophthalmology. 2008 May;115(5):830-8. doi: 10.1016/j.ophtha.2007.06.037. Epub 2007 Oct 26. Ophthalmology. 2008. PMID: 17964657
-
Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.J Cataract Refract Surg. 2009 Mar;35(3):459-65. doi: 10.1016/j.jcrs.2008.11.044. J Cataract Refract Surg. 2009. PMID: 19251138
-
Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: a meta-analysis.Am J Ophthalmol. 2007 Mar;143(3):428-36. doi: 10.1016/j.ajo.2006.11.045. Epub 2006 Dec 28. Am J Ophthalmol. 2007. PMID: 17224119
-
Complications of cataract and refractive surgery: a clinicopathological documentation.Trans Am Ophthalmol Soc. 2001;99:95-107; discussion 107-9. Trans Am Ophthalmol Soc. 2001. PMID: 11797325 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical