A prospective randomized comparison of ultrasound and neurostimulation as needle end points for interscalene catheter placement
- PMID: 19372356
- DOI: 10.1213/ane.0b013e31819c29b8
A prospective randomized comparison of ultrasound and neurostimulation as needle end points for interscalene catheter placement
Abstract
Background: In this prospective, randomized study, we tested the hypothesis that interscalene catheters placed for shoulder surgery using an ultrasound needle end point provide postoperative analgesia similar in quality to those placed using a neurostimulation needle end point. Secondary end points included needle time under the skin, procedure-related pain, and the incidence of early neurological complications.
Methods: Patients presenting for shoulder surgery were recruited. Needles introduced for catheter insertion were initially guided with out-of-plane ultrasound imaging but were prospectively randomized to either sonographic placement immediately lateral to the interscalene interface (n = 41) or to an appropriate motor response at <0.5 mA (n = 40). Catheters were then advanced blindly 2-3 cm beyond needle tip. All surgery was conducted under general anesthesia. At the end of surgery, an infusion of ropivacaine 0.2% 2 mL/h with as-required hourly 5 mL boluses was instituted and continued at home for 2-5 days. Needle time under the skin and numerical rating pain score (NRPS) during insertion were recorded. Patients recorded worst NRPS, the need for supplementary ropivacaine boluses and tramadol on postoperative days 1 and 2. All patients were questioned at Day 10 for new neurological symptoms.
Results: There was no significant difference in the worst NRPS at rest and on movement and the requirement for supplementary ropivacaine boluses or tramadol during the first 48 postoperative hours. In one patient in group ultrasound, a satisfactory ultrasound image was unobtainable. An appropriate motor response was obtained in all subjects in group neurostimulation. The median (quartiles) needle time under the skin was 78 (65-101) s in group ultrasound and 108 (94-129) s in group neurostimulation (P < 0.001). The median (quartiles) insertion NRPS was 2 (0-4) in group ultrasound and 3 (1-5) in group neurostimulation (P < 0.048). There was no difference in the frequency of neurological complications between groups.
Conclusions: Interscalene catheters placed for shoulder surgery using an ultrasound needle end point provide postoperative analgesia that is of similar quality to that obtained when using a neurostimulation needle end point. The ultrasound end point was associated with a reduction in needle under the skin time and procedure-related pain.
Similar articles
-
A prospective randomized comparison of ultrasound guidance versus neurostimulation for interscalene catheter placement.Reg Anesth Pain Med. 2009 Nov-Dec;34(6):590-4. doi: 10.1097/aap.0b013e3181ada622. Reg Anesth Pain Med. 2009. PMID: 19916253 Clinical Trial.
-
Ambulatory continuous femoral analgesia for major knee surgery: a randomised study of ultrasound-guided femoral catheter placement.Anaesth Intensive Care. 2009 Sep;37(5):758-66. doi: 10.1177/0310057X0903700514. Anaesth Intensive Care. 2009. PMID: 19775040 Clinical Trial.
-
Continuous interscalene brachial plexus block via an ultrasound-guided posterior approach: a randomized, triple-masked, placebo-controlled study.Anesth Analg. 2009 May;108(5):1688-94. doi: 10.1213/ane.0b013e318199dc86. Anesth Analg. 2009. PMID: 19372355 Free PMC article. Clinical Trial.
-
Case report: ropivacaine neurotoxicity at clinical doses in interscalene brachial plexus block.Can J Anaesth. 2007 Nov;54(11):912-6. doi: 10.1007/BF03026796. Can J Anaesth. 2007. PMID: 17975237 Review.
-
Review of interscalene block for postoperative analgesia after shoulder surgery in obese patients.Acta Anaesthesiol Taiwan. 2012 Mar;50(1):29-34. doi: 10.1016/j.aat.2012.02.001. Epub 2012 Mar 25. Acta Anaesthesiol Taiwan. 2012. PMID: 22500911 Review.
Cited by
-
Ultrasound-Guided Block of the Sciatic and the Femoral Nerves in Rabbits-A Descriptive Anatomical Study.Animals (Basel). 2023 Jul 24;13(14):2393. doi: 10.3390/ani13142393. Animals (Basel). 2023. PMID: 37508169 Free PMC article.
-
[Differences of analgesic efficacy and complication rates between ultrasound and nervestimulator guided peripheral nerve catheters : Database analysis on patient-relevant target parameters].Anaesthesist. 2014 Nov;63(11):825-31. doi: 10.1007/s00101-014-2379-7. Epub 2014 Sep 18. Anaesthesist. 2014. PMID: 25227880 German.
-
Ultrasound-guided perineural catheter insertion: three approaches but few illuminating data.Reg Anesth Pain Med. 2010 Mar-Apr;35(2):123-6. doi: 10.1097/AAP.0b013e3181d245a0. Reg Anesth Pain Med. 2010. PMID: 20216031 Free PMC article. No abstract available.
-
Electrostimulation with or without ultrasound-guidance in interscalene brachial plexus block for shoulder surgery.J Anesth. 2012 Aug;26(4):610-3. doi: 10.1007/s00540-012-1366-x. Epub 2012 Mar 4. J Anesth. 2012. PMID: 22391670 Clinical Trial.
-
Minimum Effective Volume of 0.75% Ropivacaine for Ultrasound-Guided Axillary Brachial Plexus Block.Cureus. 2020 Dec 22;12(12):e12229. doi: 10.7759/cureus.12229. Cureus. 2020. PMID: 33409105 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical