Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Apr;34(4):257-63.
doi: 10.1080/02713680902725962.

Ocular pharmacokinetics and availability of topically applied baicalein in rabbits

Affiliations

Ocular pharmacokinetics and availability of topically applied baicalein in rabbits

Li Zhang et al. Curr Eye Res. 2009 Apr.

Abstract

Purpose: To evaluate the ocular pharmacokinetics and availability of baicalein following topical application.

Methods: Hydroxypropyl beta-cyclodextrin (HP-beta -CD) was used to formulate an aqueous eye drop to improve aqueous solubility of baicalein. A single dose of either baicalein suspension (1%) (Bai-SP) or baicalein (1%)/HP-beta-CD (10%) solution (Bai-CD) was topically applied to rabbits. Aqueous humor and cornea were collected after 5, 10, 20, 30, 45, 60, 90, and 120 min. Baicalein concentrations were determined by high-performance liquid chromatography (HPLC) after extraction.

Results: After topically applying Bai-CD, the baicalein concentrations in aqueous humor were significantly increased at 20-120 min except at 90 min compared with those of Bai-SP (p < 0.05). The highest levels of baicalein in aqueous humor (Cmax, 4.11 +/- 0.75 microg/ml) were obtained after 30 min application of Bai-CD, 3.6 times greater than that corresponding to the Bai-SP at 20 min. The Bai-CD produced an over 2.1-fold bioavailability (AUC(0-120), area under the concentration time curve between 0 and 120 min) increase in aqueous humor compared to the Bai-SP. Peak baicalein concentration in cornea (56.53 +/- 17.02 microg/g) was achieved within 5 min after topical application of Bai-CD and 4.5 times higher than that of Bai-SP at the same timepoint. The baicalein levels in corneas obtained after application of Bai-CD were all much higher than those obtained by Bai-SP (p < 0.01), whereas the drug levels became undetectable 30 min after topical application of Bai-SP.

Conclusion: Bai-CD formulation is superior to Bai-SP for increasing ocular bioavailability.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources