Monitoring of the ballistocardiogram with the static charge sensitive bed
- PMID: 1937507
- DOI: 10.1109/10.83586
Monitoring of the ballistocardiogram with the static charge sensitive bed
Abstract
The static charge sensitive bed (SCSB) consists of a sensitive movement detector embedded in a mattress. When a subject rests on the bed, a single electrical signal, containing components reflective of cardiac, respiratory, and body movement related motion, is produced. This paper describes a digital signal processing technique to separate the BCG from the SCSB signal. An evaluation of this algorithm was conducted using recordings from normal volunteers. Comparisons with simultaneously recorded reference signals indicated that the algorithm performed satisfactorily in a laboratory environment.
Similar articles
-
Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings.Neuroimage. 2007 Aug 1;37(1):202-11. doi: 10.1016/j.neuroimage.2007.02.060. Epub 2007 May 18. Neuroimage. 2007. PMID: 17582785
-
A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration.Am J Physiol. 1981 May;240(5):R384-92. doi: 10.1152/ajpregu.1981.240.5.R384. Am J Physiol. 1981. PMID: 7235054
-
The validity of the static charge sensitive bed in detecting obstructive sleep apnoeas.Eur Respir J. 1988 Apr;1(4):330-6. Eur Respir J. 1988. PMID: 3396673
-
Ballistocardiography and seismocardiography: a review of recent advances.IEEE J Biomed Health Inform. 2015 Jul;19(4):1414-27. doi: 10.1109/JBHI.2014.2361732. Epub 2014 Oct 7. IEEE J Biomed Health Inform. 2015. PMID: 25312966 Review.
-
A survey of signal processing algorithms in brain-computer interfaces based on electrical brain signals.J Neural Eng. 2007 Jun;4(2):R32-57. doi: 10.1088/1741-2560/4/2/R03. Epub 2007 Mar 27. J Neural Eng. 2007. PMID: 17409474 Review.
Cited by
-
ResNet-BiLSTM: A Multiscale Deep Learning Model for Heartbeat Detection Using Ballistocardiogram Signals.J Healthc Eng. 2022 Jan 27;2022:6388445. doi: 10.1155/2022/6388445. eCollection 2022. J Healthc Eng. 2022. Retraction in: J Healthc Eng. 2023 Nov 29;2023:9809587. doi: 10.1155/2023/9809587. PMID: 35126936 Free PMC article. Retracted.
-
Unobtrusive Bed Monitor State of the Art.Sensors (Basel). 2025 Mar 18;25(6):1879. doi: 10.3390/s25061879. Sensors (Basel). 2025. PMID: 40293004 Free PMC article. Review.
-
Comparative analysis of three different modalities for characterization of the seismocardiogram.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:2899-903. doi: 10.1109/IEMBS.2009.5334444. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964786 Free PMC article.
-
Bed-Based Ballistocardiography: Dataset and Ability to Track Cardiovascular Parameters.Sensors (Basel). 2020 Dec 29;21(1):156. doi: 10.3390/s21010156. Sensors (Basel). 2020. PMID: 33383739 Free PMC article.
-
Development of a novel contactless mechanocardiograph device.Int J Telemed Appl. 2008;2008:436870. doi: 10.1155/2008/436870. Int J Telemed Appl. 2008. PMID: 18497875 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources