Two-dimensional liquid chromatography analysis of synthetic polymers using fast size exclusion chromatography at high column temperature
- PMID: 19375711
- DOI: 10.1016/j.chroma.2009.03.072
Two-dimensional liquid chromatography analysis of synthetic polymers using fast size exclusion chromatography at high column temperature
Abstract
In recent years, two-dimensional liquid chromatography (2D-LC) has been used increasingly for the analysis of synthetic polymers. A 2D-LC analysis provides richer information than a single chromatography analysis at the cost of longer analysis time. The time required for a comprehensive 2D-LC analysis is essentially proportional to the analysis time of the second dimension separation. Many of 2D-LC analyses of synthetic polymers have employed size exclusion chromatography (SEC) for the second-dimension analysis due to the relatively short analysis time in addition to the wide use in the polymer analysis. Nonetheless, short SEC columns are often used for 2D-LC analyses to reduce the separation time, which inevitably deteriorates the resolution. In this study, we demonstrated that high temperature SEC can be employed as an efficient second-LC in the 2D-LC separation of synthetic polymers. By virtue of high temperature operation (low solvent viscosity and high diffusivity of the polymer molecules), a normal length SEC column can be used at high flow rate with little loss in resolution.
Similar articles
-
A protocol for designing comprehensive two-dimensional liquid chromatography separation systems.J Chromatogr A. 2006 Jul 7;1120(1-2):282-90. doi: 10.1016/j.chroma.2005.11.039. Epub 2005 Dec 27. J Chromatogr A. 2006. PMID: 16376907
-
A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography x liquid chromatography.J Chromatogr A. 2006 Nov 10;1133(1-2):126-34. doi: 10.1016/j.chroma.2006.08.048. Epub 2006 Sep 7. J Chromatogr A. 2006. PMID: 16959256
-
Transfer-volume effects in two-dimensional chromatography: adsorption-phenomena in second-dimension size-exclusion chromatography.J Chromatogr A. 2011 Feb 25;1218(8):1147-52. doi: 10.1016/j.chroma.2010.12.080. Epub 2010 Dec 28. J Chromatogr A. 2011. PMID: 21227427
-
Implementations of two-dimensional liquid chromatography.J Chromatogr A. 2008 May 2;1189(1-2):109-68. doi: 10.1016/j.chroma.2008.01.086. Epub 2008 Feb 16. J Chromatogr A. 2008. PMID: 18336826 Review.
-
Use of polymer fiber stationary phases for liquid chromatography separations: part II--Applications.J Sep Sci. 2009 Mar;32(5-6):695-705. doi: 10.1002/jssc.200800645. J Sep Sci. 2009. PMID: 19194974 Review.
Cited by
-
Effect of first dimension phase selectivity in online comprehensive two dimensional liquid chromatography (LC×LC).J Chromatogr A. 2011 Sep 23;1218(38):6675-87. doi: 10.1016/j.chroma.2011.07.063. Epub 2011 Jul 24. J Chromatogr A. 2011. PMID: 21840009 Free PMC article.
-
Size-exclusion chromatography (SEC) of branched polymers and polysaccharides.Anal Bioanal Chem. 2011 Feb;399(4):1413-23. doi: 10.1007/s00216-010-4221-7. Epub 2010 Oct 22. Anal Bioanal Chem. 2011. PMID: 20967430 Free PMC article. Review.
-
Advances in High-Temperature Interaction Chromatography of Polyolefins: A Tutorial on Solvent and Temperature Gradient.Anal Chem. 2024 Nov 19;96(46):18311-18321. doi: 10.1021/acs.analchem.4c04247. Epub 2024 Nov 8. Anal Chem. 2024. PMID: 39515787 Free PMC article.
-
Size exclusion chromatography with superficially porous particles.J Chromatogr A. 2017 Jan 13;1480:11-19. doi: 10.1016/j.chroma.2016.12.016. Epub 2016 Dec 9. J Chromatogr A. 2017. PMID: 28007299 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources