Intermediate-term patency of saphenous vein graft with a clampless hand-sewn proximal anastomosis device after off-pump coronary bypass grafting
- PMID: 19379877
- DOI: 10.1016/j.athoracsur.2009.02.090
Intermediate-term patency of saphenous vein graft with a clampless hand-sewn proximal anastomosis device after off-pump coronary bypass grafting
Abstract
Background: To avoid complications related to aortic manipulation, devices were developed to perform clampless anastomosis. However, there are few studies concerning the late patency of the graft. The aims of this study were to investigate the patency rate of saphenous vein (SV) graft after off-pump coronary artery bypass grafting (OPCAB) and to evaluate the influence of a clampless hand-sewn proximal anastomosis on late graft patency.
Methods: Patients (n = 232) were enrolled who underwent OPCAB with SV grafts from 2004 to 2007 and had follow-up angiography. For proximal anastomoses, a clampless device was used in 73 (group A; HEARTSTRING [Guidant Corporation, Santa Clara, CA] in 54, Enclose II [Novare Surgical Systems, Inc, Cupertino, CA] in 19), and partial clamping was used in 159 (group B). The proximal anastomosis procedure was modified according to the results of epiaortic ultrasonography. Coronary angiography was performed early (11.8 +/- 10.4 days) and one-year postoperatively (n = 180, 371.5 +/- 102.6 days).
Results: There were no significant differences in patient characteristics between the two groups except for a higher reoperation rate in group A. The overall SV patency rate at the early and one-year postoperative angiography was 95.7% and 83.0%, respectively. The patency rates were similar between the two groups (early: 97.3% vs 98.1%, p = 0.729; 1 year: 87.0% vs 81.3%, p = 0.316). There was also no significant difference in the target vessel revascularization rate during follow-up (6.8% vs 10.1%, p = 0.623).
Conclusions: Intermediate-term angiographic follow-up demonstrate an acceptable SV patency rate after OPCAB. The SV patency rate with a clampless device for proximal anastomosis is comparable with that with partial clamping during the first postoperative year.
Similar articles
-
Influence of vein graft use on postoperative 1-year results after off-pump coronary artery bypass surgery.Eur J Cardiothorac Surg. 2007 Nov;32(5):718-23. doi: 10.1016/j.ejcts.2007.08.001. Epub 2007 Sep 5. Eur J Cardiothorac Surg. 2007. PMID: 17822913
-
Early and midterm patency of the proximal anastomoses of saphenous vein grafts made with a Symmetry Aortic Connector System.J Thorac Cardiovasc Surg. 2005 Oct;130(4):1028-31. doi: 10.1016/j.jtcvs.2005.05.026. J Thorac Cardiovasc Surg. 2005. PMID: 16214515
-
Twelve-month patency with the PAS-port proximal connector device: a single center prospective randomized trial.Ann Thorac Surg. 2008 May;85(5):1579-84. doi: 10.1016/j.athoracsur.2008.01.074. Ann Thorac Surg. 2008. PMID: 18442542 Clinical Trial.
-
Does a 'no-touch' technique result in better vein patency?Interact Cardiovasc Thorac Surg. 2011 Dec;13(6):626-30. doi: 10.1510/icvts.2011.281998. Epub 2011 Sep 10. Interact Cardiovasc Thorac Surg. 2011. PMID: 21908888 Review.
-
Composite arterial grafting.Expert Rev Cardiovasc Ther. 2006 Jul;4(4):523-33. doi: 10.1586/14779072.4.4.523. Expert Rev Cardiovasc Ther. 2006. PMID: 16918271 Review.
Cited by
-
Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography.BMC Cardiovasc Disord. 2009 Dec 8;9:53. doi: 10.1186/1471-2261-9-53. BMC Cardiovasc Disord. 2009. PMID: 19995414 Free PMC article.
-
A stand-up collar around the saphenous vein graft.Gen Thorac Cardiovasc Surg. 2010 Oct;58(10):546-7. doi: 10.1007/s11748-009-0579-x. Epub 2010 Oct 13. Gen Thorac Cardiovasc Surg. 2010. PMID: 20941572
MeSH terms
LinkOut - more resources
Full Text Sources
Medical