Implanted neural interfaces: biochallenges and engineered solutions
- PMID: 19400710
- DOI: 10.1146/annurev-bioeng-061008-124927
Implanted neural interfaces: biochallenges and engineered solutions
Abstract
Neural interfaces are connections that enable two-way exchange of information with the nervous system. These connections can occur at multiple levels, including with peripheral nerves, with the spinal cord, or with the brain; in many instances, fundamental biophysical and biological challenges are shared across these levels. We review these challenges, including selectivity, stability, resolution versus invasiveness, implant-induced injury, and the host-interface response. Subsequently, we review the engineered solutions to these challenges, including electrode designs and geometry, stimulation waveforms, materials, and surface modifications. Finally, we consider emerging opportunities to improve neural interfaces, including cellular-level silicon to neuron connections, optical stimulation, and approaches to control inflammation. Overcoming the biophysical and biological challenges will enable effective high-density neural interfaces for stimulation and recording.
Similar articles
-
Bidirectional interfaces with the peripheral nervous system.Int Rev Neurobiol. 2009;86:23-38. doi: 10.1016/S0074-7742(09)86002-9. Int Rev Neurobiol. 2009. PMID: 19607988 Review.
-
Implantable microscale neural interfaces.Biomed Microdevices. 2007 Dec;9(6):923-38. doi: 10.1007/s10544-006-9045-z. Biomed Microdevices. 2007. PMID: 17252207 Review.
-
Conducting polymers for neural interfaces: challenges in developing an effective long-term implant.Biomaterials. 2008 Aug-Sep;29(24-25):3393-9. doi: 10.1016/j.biomaterials.2008.04.047. Epub 2008 May 23. Biomaterials. 2008. PMID: 18501423 Review.
-
Microengineered neural probes for in vivo recording.Methods Mol Biol. 2010;583:135-48. doi: 10.1007/978-1-60327-106-6_6. Methods Mol Biol. 2010. PMID: 19763463 Review.
-
Brain-computer interfaces: an overview of the hardware to record neural signals from the cortex.Prog Brain Res. 2009;175:297-315. doi: 10.1016/S0079-6123(09)17521-0. Prog Brain Res. 2009. PMID: 19660664 Review.
Cited by
-
Influence of probe flexibility and gelatin embedding on neuronal density and glial responses to brain implants.PLoS One. 2015 Mar 19;10(3):e0119340. doi: 10.1371/journal.pone.0119340. eCollection 2015. PLoS One. 2015. PMID: 25790172 Free PMC article.
-
Modality-specific axonal regeneration: toward selective regenerative neural interfaces.Front Neuroeng. 2011 Oct 12;4:11. doi: 10.3389/fneng.2011.00011. eCollection 2011. Front Neuroeng. 2011. PMID: 22016734 Free PMC article.
-
A bidirectional brain-machine interface algorithm that approximates arbitrary force-fields.PLoS One. 2014 Mar 13;9(3):e91677. doi: 10.1371/journal.pone.0091677. eCollection 2014. PLoS One. 2014. PMID: 24626393 Free PMC article.
-
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review.J Neuroeng Rehabil. 2020 Mar 10;17(1):43. doi: 10.1186/s12984-020-00667-5. J Neuroeng Rehabil. 2020. PMID: 32151268 Free PMC article. Review.
-
Mechano-sensitization of mammalian neuronal networks through expression of the bacterial large-conductance mechanosensitive ion channel.J Cell Sci. 2018 Mar 8;131(5):jcs210393. doi: 10.1242/jcs.210393. J Cell Sci. 2018. PMID: 29361543 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources