Introduction: Nickel-titanium rotary instruments reduce procedural errors and the time required to finish root canal preparation. The goal of this study was to evaluate the effectiveness of a manual glide path on the preparation of curved root canals with Mtwo rotary system.
Methods: Forty buccal root canals with angles of curvature between 25 to 76 degrees were randomly divided into 4 groups (n = 10); 2 groups were instrumented with Mtwo instruments to the full length, and in the other 2 groups a glide path with #08-15 K files was performed before instrumentation with Mtwo system. Digital double radiographic technique was used to determine apical transportation and the change in angle of curvature. Also working time was calculated.
Results: No statistically significant differences in the angle of canal curvature, apical transportation, and the working time were found between groups with glide path and no glide path. No significant differences were found when comparing the results of 3 variables between degrees of curvature.
Conclusion: The use of a manual glide path before Mtwo rotary system did not influence the apical transportation in curved root canals.
Similar articles
-
Comparison among manual instruments and PathFile and Mtwo rotary instruments to create a glide path in the root canal preparation of curved canals.J Endod. 2012 Jan;38(1):117-20. doi: 10.1016/j.joen.2011.10.001. Epub 2011 Nov 17. J Endod. 2012. PMID: 22152634 Clinical Trial.
-
Evaluation of a new nickel-titanium system to create the glide path in root canal preparation of curved canals.J Endod. 2013 Dec;39(12):1581-4. doi: 10.1016/j.joen.2013.06.037. Epub 2013 Oct 13. J Endod. 2013. PMID: 24238451
-
Rotary Mtwo system versus manual K-file instruments: efficacy in preparing primary and permanent molar root canals.Indian J Dent Res. 2011 Mar-Apr;22(2):363. doi: 10.4103/0970-9290.84283. Indian J Dent Res. 2011. PMID: 21891918 Clinical Trial.
-
Nickel-titanium rotary systems: review of existing instruments and geometries.Dent Today. 2000 Oct;19(10):86-8, 90-5. Dent Today. 2000. PMID: 12524811 Review. No abstract available.
-
Association of manual or engine-driven glide path preparation with canal centring and apical transportation: a systematic review.Int Endod J. 2018 Nov;51(11):1239-1252. doi: 10.1111/iej.12943. Epub 2018 Jun 5. Int Endod J. 2018. PMID: 29704465
Cited by
-
Influence of a glide path on the dentinal crack formation of ProTaper Next system.Restor Dent Endod. 2015 Nov;40(4):286-9. doi: 10.5395/rde.2015.40.4.286. Epub 2015 Sep 2. Restor Dent Endod. 2015. PMID: 26587414 Free PMC article.
-
Glide Path in Endodontics: A Literature Review of Current Knowledge.Dent J (Basel). 2024 Aug 14;12(8):257. doi: 10.3390/dj12080257. Dent J (Basel). 2024. PMID: 39195101 Free PMC article. Review.
-
Comparison of PathFile and ProFinder Systems to Create a Glide Path in Curved Root Canals.Eur Endod J. 2018 Mar 6;3(1):61-65. doi: 10.14744/eej.2018.75047. eCollection 2018. Eur Endod J. 2018. PMID: 32161857 Free PMC article.
-
Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method.J Dent (Tehran). 2015 Jul;12(7):469-77. J Dent (Tehran). 2015. PMID: 26877736 Free PMC article.
-
Maintenance Evaluation of the Original Anatomy of the Root Canal Diameters Instrumented with Mtwo and BioRace Systems.Maedica (Bucur). 2020 Dec;15(4):484-489. doi: 10.26574/maedica.2020.15.4.484. Maedica (Bucur). 2020. PMID: 33603906 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources