Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 May 6:9:53.
doi: 10.1186/1471-2334-9-53.

Sensitivity of direct versus concentrated sputum smear microscopy in HIV-infected patients suspected of having pulmonary tuberculosis

Affiliations

Sensitivity of direct versus concentrated sputum smear microscopy in HIV-infected patients suspected of having pulmonary tuberculosis

Adithya Cattamanchi et al. BMC Infect Dis. .

Abstract

Background: Sputum concentration increases the sensitivity of smear microscopy for the diagnosis of tuberculosis (TB), but few studies have investigated this method in human immunodeficiency virus (HIV)-infected individuals.

Methods: We performed a prospective, blinded evaluation of direct and concentrated Ziehl-Neelsen smear microscopy on a single early-morning sputum sample in HIV-infected patients with > 2 weeks of cough hospitalized in Kampala, Uganda. Direct and concentrated smear results were compared with results of Lowenstein-Jensen culture.

Results: Of 279 participants, 170 (61%) had culture-confirmed TB. The sensitivity of direct and concentrated smear microscopy was not significantly different (51% vs. 52%, difference 1%, 95% confidence interval (CI): [-7%, 10%], p = 0.88). However, when results of both direct and concentrated smears were considered together, sensitivity was significantly increased compared with either method alone (64%, 95% CI: [56%, 72%], p < 0.01 for both comparisons) and was similar to that of direct smear results from consecutive (spot and early-morning) specimens (64% vs. 63%, difference 1%, 95% CI: [-6%, 8%], p = 0.85). Among 109 patients with negative cultures, one had a positive direct smear and 12 had positive concentrated smears (specificity 99% vs. 89%, difference 10%, 95% CI: [2%, 18%], p = 0.003). Of these 13 patients, 5 (38%) had improved on TB therapy after two months.

Conclusion: Sputum concentration did not increase the sensitivity of light microscopy for TB diagnosis in this HIV-infected population. Given the resource requirements for sputum concentration, additional studies using maximal blinding, high-quality direct microscopy, and a rigorous gold standard should be conducted before universally recommending this technique.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Study Flow Diagram.

References

    1. World Health Organization. Global tuberculosis control 2008: surveillance, planning, financing. Geneva: WHO; 2008.
    1. Albert H. Economic analysis of the diagnosis of smear-negative pulmonary tuberculosis in South Africa: incorporation of a new rapid test, FASTPlaqueTB, into the diagnostic algorithm. Int J Tuberc Lung Dis. 2004;8:240–247. - PubMed
    1. Suarez PG, Floyd K, Portocarrero J, Alarcon E, Rapiti E, Ramos G. Feasibility and cost-effectiveness of standardised second-line drug treatment for chronic tuberculosis patients: a national cohort study in Peru. Lancet. 2002;359:1980–1989. doi: 10.1016/S0140-6736(02)08830-X. - DOI - PubMed
    1. van Cleeff M, Kivihya-Ndugga L, Githui W, Ng'ang'a L, Kibuga D, Odhiambo J. Cost-effectiveness of polymerase chain reaction versus Ziehl-Neelsen smear microscopy for diagnosis of tuberculosis in Kenya. Int J Tuberc Lung Dis. 2005;9:877–883. - PubMed
    1. Keeler E, Perkins MD, Small P, Hanson C, Reed S, Cunningham J. Reducing the global burden of tuberculosis: the contribution of improved diagnostics. Nature. 2006;444(Suppl 1):49–57. doi: 10.1038/nature05446. - DOI - PubMed

Publication types