Reproducibility of hepatic triglyceride content assessment in normals using localized magnetic resonance spectroscopy
- PMID: 19422403
- DOI: 10.1111/j.1463-1326.2008.00979.x
Reproducibility of hepatic triglyceride content assessment in normals using localized magnetic resonance spectroscopy
Abstract
Aim: To investigate the reproducibility of measurements of hepatic triglyceride content (HTGC) in subjects with normal HTGC using localized (1)H-magnetic resonance spectroscopy ((1)H-MRS) and a clinical 1.5T scanner.
Methods: The (1)H-MRS acquisition was performed with a common protocol using the whole-body coil and no respiratory triggering. An upper limit of normal HTGC of 5.56% was used. Duplicate measurements, including subject repositioning, were acquired from 23 subjects, 19 of whom had a normal HTGC.
Results: The mean coefficient of variation (CV) from the duplicate measurements was 14.8% (20.5% before exclusion of a subject who was considered to be an outlier). Mean CVs of subgroups below and above the 1% HTGC limit were 19.8 and 7.0 respectively.
Conclusions: The mean CV calculated in subjects with HTGC in the normal range was found to be higher than CVs of wide range HTGC groups reported in the literature. It is concluded that the reproducibility of HTGC measurements using (1)H-MRS depends on the HTGC range. These findings are of importance in reproducibility studies and in estimations of required study group sizes.
Similar articles
-
Magnetic resonance spectroscopy to measure hepatic triglyceride content: prevalence of hepatic steatosis in the general population.Am J Physiol Endocrinol Metab. 2005 Feb;288(2):E462-8. doi: 10.1152/ajpendo.00064.2004. Epub 2004 Aug 31. Am J Physiol Endocrinol Metab. 2005. PMID: 15339742 Clinical Trial.
-
Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content.J Magn Reson Imaging. 2009 Aug;30(2):444-8. doi: 10.1002/jmri.21837. J Magn Reson Imaging. 2009. PMID: 19629974
-
Intraindividual variability of striatal (1)H-MRS brain metabolite measurements at 3 T.Magn Reson Imaging. 2006 Feb;24(2):187-94. doi: 10.1016/j.mri.2005.10.027. Epub 2005 Dec 27. Magn Reson Imaging. 2006. PMID: 16455408
-
Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: reproducibility and sensitivity of the method.Am J Physiol Endocrinol Metab. 2005 Nov;289(5):E935-9. doi: 10.1152/ajpendo.00095.2005. Epub 2005 Jun 21. Am J Physiol Endocrinol Metab. 2005. PMID: 15972271
-
Reproducibility of GABA measurements using 2D J-resolved magnetic resonance spectroscopy.Magn Reson Imaging. 2007 Jun;25(5):634-40. doi: 10.1016/j.mri.2006.10.010. Epub 2006 Nov 30. Magn Reson Imaging. 2007. PMID: 17540274
Cited by
-
Intrahepatic Fat Content and Markers of Hepatic Fibrosis in Obese Children.Int J Endocrinol. 2016;2016:4890974. doi: 10.1155/2016/4890974. Epub 2016 Feb 4. Int J Endocrinol. 2016. PMID: 26966436 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources